{"id":3237,"date":"2020-09-14T01:41:56","date_gmt":"2020-09-14T01:41:56","guid":{"rendered":"https:\/\/longchangchemical.com\/?p=3237"},"modified":"2026-04-28T10:41:46","modified_gmt":"2026-04-28T10:41:46","slug":"analytical-instruments-2","status":"publish","type":"post","link":"https:\/\/longchangchemical.com\/tr\/analytical-instruments-2\/","title":{"rendered":"Longchang Kimya Laboratuvar\u0131 taraf\u0131ndan sat\u0131n al\u0131nan Analitik Cihazlar\uff082\uff09"},"content":{"rendered":"<h4 class=\"wp-block-heading\">1. NMR<\/h4>\n\n<!-- lc-qa-start -->\n<p><strong>Quick answer:<\/strong> For general industrial-chemical topics, the safest commercial decision usually comes from checking application fit, specification, process compatibility, and handling requirements together instead of relying on one simplified rule.<\/p>\n<!-- lc-qa-end -->\n\n\n\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"453\" height=\"603\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg\" alt=\"\" class=\"wp-image-3238\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg 453w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy-225x300.jpg 225w\" sizes=\"(max-width: 453px) 100vw, 453px\" \/><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">\u0130ngilizce ad\u0131: Nuclear Magnetic Resonance Spectroscopy<br>Model ARX400<br>\u00dcretici firma: Bruker<br>K\u00f6ken: \u0130svi\u00e7re<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">Teknik g\u00f6stergeler: \u00e7\u00f6z\u00fcn\u00fcrl\u00fck: H, C 0,2 Hz'e e\u015fit veya daha azd\u0131r; sbr hassasiyeti: H 390:1 (5 mm 0.1% EB), C 150:1 (5 mm 10% EB); sbr hat tipi: H 0,55% &lt;10 Hz&#039;de, 0,11% &lt;5 Hz&#039;de; C 0,55% &lt;3 Hz&#039;de, 0,11% &lt;7 Hz&#039;de.<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">Fonksiyon: H, C ve Ag'den P'ye kadar \u00e7e\u015fitli \u00e7ekirdeklerin NMR spektrumlar\u0131n\u0131 \u00f6l\u00e7ebilir; \u00e7e\u015fitli darbe programlar\u0131 ile donat\u0131lm\u0131\u015f, geleneksel H ve C tek boyutlu spektrumlara ek olarak, DEPT, homon\u00fckleer ve heteron\u00fckleer korelasyon, HMBC vb. i\u00e7in de kullan\u0131labilir. Boyutlu ve iki boyutlu deneyler; kimya, biyoloji, petrokimya, do\u011fal \u00fcr\u00fcnler vb. alanlarda molek\u00fcler yap\u0131 analizi, i\u00e7erik belirleme ve reaksiyon mekanizmas\u0131 ara\u015ft\u0131rmalar\u0131 i\u00e7in uygundur.<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">\u00c7al\u0131\u015fma prensibi: G\u00fc\u00e7l\u00fc bir manyetik alanda, n\u00fckleer spine sahip \u00e7ekirdek enerji seviyesi b\u00f6l\u00fcnmesine u\u011frar. Harici elektromanyetik radyasyon absorbe edildi\u011finde, n\u00fckleer enerji seviyesi ge\u00e7i\u015fi meydana gelebilir. Harici radyo frekans alan\u0131n\u0131n frekans\u0131, n\u00fckleer spin presesyonunun frekans\u0131 ile ayn\u0131 oldu\u011funda, radyo frekans alan\u0131n\u0131n enerjisi, enerji seviyesi ge\u00e7i\u015fi i\u00e7in enerji sa\u011flamak \u00fczere \u00e7ekirdek taraf\u0131ndan etkili bir \u015fekilde absorbe edilebilir. Bu nedenle, farkl\u0131 atom \u00e7ekirdekleri, farkl\u0131 y\u00fck koruma etkileri alt\u0131nda (yani, farkl\u0131 kimyasal ortamlar), belirli bir harici manyetik alanda, yaln\u0131zca belirli bir frekans radyo frekans\u0131 alan\u0131 taraf\u0131ndan sa\u011flanan enerjiyi emer, b\u00f6ylece atomun bulundu\u011fu kimyasal ortam\u0131 analiz edebilen ve ba\u011f\u0131n \u015feklini \u00e7\u0131karabilen bir n\u00fckleer manyetik rezonans sinyali olu\u015fturur.<\/h5>\n\n\n\n<h4 class=\"wp-block-heading\">2. GC-MS<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"784\" height=\"523\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/GC-MS.jpg\" alt=\"\" class=\"wp-image-3239\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/GC-MS.jpg 784w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/GC-MS-300x200.jpg 300w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/GC-MS-768x512.jpg 768w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/GC-MS-600x400.jpg 600w\" sizes=\"(max-width: 784px) 100vw, 784px\" \/><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">\u0130ngilizce ad\u0131: GC-MS<br>Model: 7980A\/5975C<br>\u00dcretici firma: Agilent<br>K\u00f6ken: Birle\u015fik Devletler<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">Teknik g\u00f6stergeler: K\u00fctle aral\u0131\u011f\u0131: 10-1000 \u00d6l\u00e7\u00fclebilir iyon tipi: EI (pozitif iyon); 7890 A gaz kromatograf\u0131, b\u00f6l\u00fcnm\u00fc\u015f\/b\u00f6l\u00fcnmemi\u015f giri\u015f, EPC ile; 5975B MSD (EI kayna\u011f\u0131), molek\u00fcler turbo pompa (262 litre) \/Sn); 100 \u00f6rnek tepsili 7863 otomatik s\u0131v\u0131 \u00f6rnekleyici; NIST 05 spektral k\u00fct\u00fcphane<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">\u0130\u015flev: K\u00fc\u00e7\u00fck organik molek\u00fcllerin kalitatif ve kantitatif analizi, d\u00fc\u015f\u00fck kaynama noktal\u0131 organik bile\u015fiklerin ayr\u0131\u015ft\u0131r\u0131lmas\u0131 ve analizi.<\/h5>\n\n\n\n<h4 class=\"wp-block-heading\">3. Torpido g\u00f6z\u00fc<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"800\" height=\"400\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Vacuum-Glove-Box.jpg\" alt=\"\" class=\"wp-image-3240\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Vacuum-Glove-Box.jpg 800w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Vacuum-Glove-Box-300x150.jpg 300w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Vacuum-Glove-Box-768x384.jpg 768w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Vacuum-Glove-Box-600x300.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">\u0130ngilizce ad\u0131: Vacuum Glove Box<br>Model: lab2000 tek istasyonlu entegre tek tarafl\u0131 eldiven kutusu<br>\u00dcretici firma: Etex<br>\u00c7in mal\u0131<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">Teknik g\u00f6stergeler: su i\u00e7eri\u011fi 0-1000 ppm, art\u0131 veya eksi 1% PPM, oksijen analiz\u00f6r\u00fc 0-1000 ppm, art\u0131 veya eksi 1% ppm<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">\u0130\u015flev: Eldiven kutusu genellikle uygulama s\u0131ras\u0131nda y\u00fcksek safl\u0131kta inert gazla doldurulur ve gazdaki oksijen, su buhar\u0131, organik gaz ve di\u011fer safs\u0131zl\u0131klar eldiven kutusunun sirk\u00fclasyon sistemi arac\u0131l\u0131\u011f\u0131yla filtrelenir. Susuz, oksijensiz ve tozsuz ortamda yayg\u0131n olarak kullan\u0131l\u0131r Ultra saf ortam, kutudaki reaktifleri ve su ve oksijenden korkan numuneleri korur, b\u00f6ylece havada ger\u00e7ekle\u015ftirilemeyen reaksiyonlar sorunsuz bir \u015fekilde ilerler.<\/h5>\n\n\n\n<h4 class=\"wp-block-heading\">4. UV-Vis<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1030\" height=\"773\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/UV-VIS-NIR-SPECTROPHOTOMETER-1030x773.jpg\" alt=\"\" class=\"wp-image-3241\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/UV-VIS-NIR-SPECTROPHOTOMETER-1030x773.jpg 1030w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/UV-VIS-NIR-SPECTROPHOTOMETER-300x225.jpg 300w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/UV-VIS-NIR-SPECTROPHOTOMETER-768x576.jpg 768w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/UV-VIS-NIR-SPECTROPHOTOMETER-600x450.jpg 600w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/UV-VIS-NIR-SPECTROPHOTOMETER.jpg 1269w\" sizes=\"(max-width: 1030px) 100vw, 1030px\" \/><\/figure>\n\n\n\n<p>\u0130ngilizce ad\u0131: UV-VIS-NIR SPECTROPHOTOMETER<br>Model UV3600Plus<br>\u00dcretici firma: Shimadzu<br>K\u00f6ken: Japonya<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Teknik g\u00f6stergeler: Tarama aral\u0131\u011f\u0131: 185-3300 nm S\u0131cakl\u0131k de\u011fi\u015fim ekipman\u0131: CPS (10-60 \u2103) Harici sirk\u00fclasyonlu su banyosu (10-60 \u2103) 60 mm entegre k\u00fcre, 150 mm b\u00fcy\u00fck entegre k\u00fcre de\u011fi\u015fken a\u00e7\u0131l\u0131 mutlak ayna yans\u0131tma aksesuar\u0131 CPS elektrik art\u0131 Termoelektrik so\u011futma cihaz\u0131, membran \u00f6rnek tutucu, 6 h\u00fccreli \u00f6rnek tutucu, sabit s\u0131cakl\u0131k su banyosu tutucu<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">Fonksiyon: s\u0131v\u0131, kat\u0131, film \u00f6rneklerini test edebilir 185-3300 nm absorpsiyon, yans\u0131ma, iletim, enerji, film kal\u0131nl\u0131\u011f\u0131 malzeme karakterizasyonu, yap\u0131 tan\u0131mlama i\u00e7in test edilebilir<\/h5>\n\n\n\n<h4 class=\"wp-block-heading\">5. S\u0131cak a\u011f\u0131rl\u0131k<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1000\" height=\"870\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/TGA-DSC-DTA.jpg\" alt=\"\" class=\"wp-image-3242\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/TGA-DSC-DTA.jpg 1000w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/TGA-DSC-DTA-300x261.jpg 300w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/TGA-DSC-DTA-768x668.jpg 768w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/TGA-DSC-DTA-600x522.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">\u0130ngilizce ad\u0131: TGA-DSC-DTA<br>Model Q600 SDT<br>\u00dcretici firma: TA<br>K\u00f6ken: Birle\u015fik Devletler<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">Teknik g\u00f6stergeler: Senkron TGA\/DSC\/DTA \u00f6l\u00e7\u00fcm\u00fc. Terazi hassasiyeti: 0.1ug Test s\u0131cakl\u0131\u011f\u0131 aral\u0131\u011f\u0131: oda s\u0131cakl\u0131\u011f\u0131 ila 1200 \u2103.<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">Fonksiyon: Termogravimetrik analiz, \u0131s\u0131tma veya sabit s\u0131cakl\u0131k i\u015flemi s\u0131ras\u0131nda s\u0131cakl\u0131\u011f\u0131n veya zaman\u0131n bir fonksiyonu olarak numunenin kalitesini g\u00f6zlemlemektir. Malzeme termal kararl\u0131l\u0131\u011f\u0131, ayr\u0131\u015fma, redoks, adsorpsiyon ve desorpsiyon, serbest su ve kristal su i\u00e7eri\u011fi ve bile\u015fim oran\u0131 hesaplamas\u0131n\u0131 inceleyin. DSC i\u015flevi, y\u00fcksek s\u0131cakl\u0131k b\u00f6lgesindeki faz de\u011fi\u015fimini, reaksiyon s\u0131cakl\u0131\u011f\u0131n\u0131, reaksiyon \u0131s\u0131s\u0131n\u0131 ve yanma \u0131s\u0131s\u0131n\u0131 analiz etmeye yard\u0131mc\u0131 olur.<\/h5>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>\u015eimdi Bize Ula\u015f\u0131n!<\/strong><\/h4>\n\n\n\n<h6 class=\"wp-block-heading\">\u00d6zelle\u015ftirilmi\u015f hizmetleri kabul ediyoruz, genellikle 24 saat i\u00e7inde sizinle ileti\u015fime ge\u00e7ece\u011fiz. Ayr\u0131ca mesai saatleri i\u00e7inde (8:30 - 6:00 UTC+8 Pzt.~Sat.) info@longchangchemical.com adresine e-posta g\u00f6nderebilir veya h\u0131zl\u0131 yan\u0131t almak i\u00e7in web sitesi canl\u0131 sohbetini kullanabilirsiniz.<\/h6>\n\n\n\n<h4 class=\"wp-block-heading\">Bu makale Longchang Kimya Ar-Ge Departman\u0131 taraf\u0131ndan yaz\u0131lm\u0131\u015ft\u0131r. Kopyalaman\u0131z ve yeniden basman\u0131z gerekiyorsa, l\u00fctfen kayna\u011f\u0131 belirtin<\/h4>\n\n\n<!-- lc-commercial-start -->\n<h2>How technical buyers usually evaluate this chemical topic<\/h2>\n<p>General chemical decisions usually become clearer when teams move from theory to application fit: what the material needs to do, how pure it needs to be, how it behaves in the real process, and what downstream constraints it must satisfy.<\/p>\n<ul>\n<li><strong>Define the use case first:<\/strong> laboratory understanding and industrial purchasing often need different levels of specification detail.<\/li>\n<li><strong>Check process compatibility:<\/strong> handling, blending, stability, and downstream interaction often determine whether a material is practical to use.<\/li>\n<li><strong>Review storage and transport behavior:<\/strong> shelf life, moisture sensitivity, temperature range, and packaging can all matter commercially.<\/li>\n<li><strong>Use sample validation when the application is critical:<\/strong> small-scale confirmation often saves the most time before a full purchasing decision.<\/li>\n<\/ul>\n<h3>FAQ for buyers and formulators<\/h3>\n<p><strong>Why can a material that looks correct on paper still underperform in use?<\/strong><br \/>Because real-world process conditions, substrate interaction, and storage behavior can reveal problems that are not obvious in a simplified specification review.<\/p>\n<p><strong>Should technical chemical selection always start with the lowest-cost option?<\/strong><br \/>Not usually. The lowest purchase price is not always the lowest use cost once process fit, stability, and downstream quality are considered.<\/p>\n<!-- lc-commercial-end -->","protected":false},"excerpt":{"rendered":"<p>1. NMR English name: Nuclear Magnetic Resonance SpectroscopyModel: ARX400Manufacturer: BrukerOrigin: Switzerland Technical indicators: resolution: H, C are less than or equal to 0.2 Hz; sbr sensitivity: H 390:1 (5 mm<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[106],"tags":[],"class_list":["post-3237","post","type-post","status-publish","format-standard","hentry","category-laboratory-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Analytical Instruments purchased by Longchang Chemical Laboratory\uff082\uff09 - Longchang Chemical<\/title>\n<meta name=\"description\" content=\"1. NMR English name: Nuclear Magnetic Resonance SpectroscopyModel: ARX400Manufacturer: BrukerOrigin: Switzerland Technical indicators: resolution: H, C...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longchangchemical.com\/tr\/analytical-instruments-2\/\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Analytical Instruments purchased by Longchang Chemical Laboratory\uff082\uff09 - Longchang Chemical\" \/>\n<meta property=\"og:description\" content=\"1. NMR English name: Nuclear Magnetic Resonance SpectroscopyModel: ARX400Manufacturer: BrukerOrigin: Switzerland Technical indicators: resolution: H, C...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longchangchemical.com\/tr\/analytical-instruments-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Longchang Chemical\" \/>\n<meta property=\"article:published_time\" content=\"2020-09-14T01:41:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-28T10:41:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"453\" \/>\n\t<meta property=\"og:image:height\" content=\"603\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Longchang Chemical\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/\"},\"author\":{\"name\":\"Longchang Chemical\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e\"},\"headline\":\"Analytical Instruments purchased by Longchang Chemical Laboratory\uff082\uff09\",\"datePublished\":\"2020-09-14T01:41:56+00:00\",\"dateModified\":\"2026-04-28T10:41:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/\"},\"wordCount\":882,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg\",\"articleSection\":[\"Laboratory News\"],\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/longchangchemical.com\/analytical-instruments-2\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/\",\"url\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/\",\"name\":\"Analytical Instruments purchased by Longchang Chemical Laboratory\uff082\uff09 - Longchang Chemical\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg\",\"datePublished\":\"2020-09-14T01:41:56+00:00\",\"dateModified\":\"2026-04-28T10:41:46+00:00\",\"description\":\"1. NMR English name: Nuclear Magnetic Resonance SpectroscopyModel: ARX400Manufacturer: BrukerOrigin: Switzerland Technical indicators: resolution: H, C...\",\"breadcrumb\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/longchangchemical.com\/analytical-instruments-2\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/#primaryimage\",\"url\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg\",\"contentUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/longchangchemical.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Analytical Instruments purchased by Longchang Chemical Laboratory\uff082\uff09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/longchangchemical.com\/#website\",\"url\":\"https:\/\/longchangchemical.com\/\",\"name\":\"Longchang Chemical\",\"description\":\"China chemical manufacturer \uff06 supplier\",\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/longchangchemical.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"tr\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/longchangchemical.com\/#organization\",\"name\":\"Longchang Chemical\",\"url\":\"https:\/\/longchangchemical.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"contentUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"width\":512,\"height\":512,\"caption\":\"Longchang Chemical\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e\",\"name\":\"Longchang Chemical\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g\",\"caption\":\"Longchang Chemical\"},\"sameAs\":[\"https:\/\/longchangchemical.com\"],\"url\":\"https:\/\/longchangchemical.com\/tr\/author\/infolongchangchemical-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Longchang Kimya Laboratuvar\u0131 taraf\u0131ndan sat\u0131n al\u0131nan Analitik Cihazlar\uff082\uff09 - Longchang Kimya","description":"1. NMR English name: Nuclear Magnetic Resonance SpectroscopyModel: ARX400Manufacturer: BrukerOrigin: Switzerland Technical indicators: resolution: H, C...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longchangchemical.com\/tr\/analytical-instruments-2\/","og_locale":"tr_TR","og_type":"article","og_title":"Analytical Instruments purchased by Longchang Chemical Laboratory\uff082\uff09 - Longchang Chemical","og_description":"1. NMR English name: Nuclear Magnetic Resonance SpectroscopyModel: ARX400Manufacturer: BrukerOrigin: Switzerland Technical indicators: resolution: H, C...","og_url":"https:\/\/longchangchemical.com\/tr\/analytical-instruments-2\/","og_site_name":"Longchang Chemical","article_published_time":"2020-09-14T01:41:56+00:00","article_modified_time":"2026-04-28T10:41:46+00:00","og_image":[{"width":453,"height":603,"url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg","type":"image\/jpeg"}],"author":"Longchang Chemical","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/#article","isPartOf":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/"},"author":{"name":"Longchang Chemical","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e"},"headline":"Analytical Instruments purchased by Longchang Chemical Laboratory\uff082\uff09","datePublished":"2020-09-14T01:41:56+00:00","dateModified":"2026-04-28T10:41:46+00:00","mainEntityOfPage":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/"},"wordCount":882,"commentCount":0,"publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"image":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/#primaryimage"},"thumbnailUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg","articleSection":["Laboratory News"],"inLanguage":"tr","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/longchangchemical.com\/analytical-instruments-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/","url":"https:\/\/longchangchemical.com\/analytical-instruments-2\/","name":"Longchang Kimya Laboratuvar\u0131 taraf\u0131ndan sat\u0131n al\u0131nan Analitik Cihazlar\uff082\uff09 - Longchang Kimya","isPartOf":{"@id":"https:\/\/longchangchemical.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/#primaryimage"},"image":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/#primaryimage"},"thumbnailUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg","datePublished":"2020-09-14T01:41:56+00:00","dateModified":"2026-04-28T10:41:46+00:00","description":"1. NMR English name: Nuclear Magnetic Resonance SpectroscopyModel: ARX400Manufacturer: BrukerOrigin: Switzerland Technical indicators: resolution: H, C...","breadcrumb":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/#breadcrumb"},"inLanguage":"tr","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longchangchemical.com\/analytical-instruments-2\/"]}]},{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/#primaryimage","url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg","contentUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Nuclear-Magnetic-Resonance-Spectroscopy.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/longchangchemical.com\/analytical-instruments-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/longchangchemical.com\/"},{"@type":"ListItem","position":2,"name":"Analytical Instruments purchased by Longchang Chemical Laboratory\uff082\uff09"}]},{"@type":"WebSite","@id":"https:\/\/longchangchemical.com\/#website","url":"https:\/\/longchangchemical.com\/","name":"Longchang Kimya","description":"\u00c7in kimyasal \u00fcreticisi \uff06 tedarik\u00e7isi","publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longchangchemical.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"tr"},{"@type":"Organization","@id":"https:\/\/longchangchemical.com\/#organization","name":"Longchang Kimya","url":"https:\/\/longchangchemical.com\/","logo":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/","url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","contentUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","width":512,"height":512,"caption":"Longchang Chemical"},"image":{"@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e","name":"Longchang Kimya","image":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g","caption":"Longchang Chemical"},"sameAs":["https:\/\/longchangchemical.com"],"url":"https:\/\/longchangchemical.com\/tr\/author\/infolongchangchemical-com\/"}]}},"_links":{"self":[{"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/posts\/3237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/comments?post=3237"}],"version-history":[{"count":4,"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/posts\/3237\/revisions"}],"predecessor-version":[{"id":9077,"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/posts\/3237\/revisions\/9077"}],"wp:attachment":[{"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/media?parent=3237"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/categories?post=3237"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/longchangchemical.com\/tr\/wp-json\/wp\/v2\/tags?post=3237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}