{"id":6555,"date":"2024-01-24T05:57:06","date_gmt":"2024-01-24T05:57:06","guid":{"rendered":"https:\/\/longchangchemical.com\/?p=6555"},"modified":"2026-04-28T10:42:24","modified_gmt":"2026-04-28T10:42:24","slug":"what-are-some-tips-for-using-a-chromatography-injection-needle","status":"publish","type":"post","link":"https:\/\/longchangchemical.com\/pt\/what-are-some-tips-for-using-a-chromatography-injection-needle\/","title":{"rendered":"Quais s\u00e3o algumas dicas para usar uma agulha de inje\u00e7\u00e3o cromatogr\u00e1fica?"},"content":{"rendered":"<p>A agulha de inje\u00e7\u00e3o cromatogr\u00e1fica \u00e9 pequena, mas indispens\u00e1vel; a agulha de inje\u00e7\u00e3o \u00e9 conectada \u00e0 amostra e aos canais do instrumento anal\u00edtico; com a agulha de inje\u00e7\u00e3o, a amostra pode entrar na coluna cromatogr\u00e1fica, atrav\u00e9s do detector, para an\u00e1lise espectral cont\u00ednua; portanto, a manuten\u00e7\u00e3o e a limpeza da agulha de inje\u00e7\u00e3o s\u00e3o os analistas que precisam prestar aten\u00e7\u00e3o ao foco di\u00e1rio; caso contr\u00e1rio, isso n\u00e3o s\u00f3 afetar\u00e1 a efici\u00eancia do trabalho, mas tamb\u00e9m prejudicar\u00e1 o instrumento.<\/p>\n<p>&nbsp;<\/p>\n<p>Classifica\u00e7\u00e3o da agulha de amostragem<\/p>\n<p>De acordo com a apar\u00eancia da agulha de alimenta\u00e7\u00e3o, ela pode ser dividida em agulha de alimenta\u00e7\u00e3o de agulha redonda em formato de espinha, agulha de alimenta\u00e7\u00e3o de agulha chanfrada e agulha de alimenta\u00e7\u00e3o de cabe\u00e7a plana.<\/p>\n<p>A agulha cil\u00edndrica, usada para amostragem do espa\u00e7ador, pode reduzir os danos ao espa\u00e7ador, suportar v\u00e1rias inje\u00e7\u00f5es e \u00e9 usada principalmente para o amostrador autom\u00e1tico; a agulha chanfrada, dispon\u00edvel no espa\u00e7ador de amostragem, facilita a opera\u00e7\u00e3o de alimenta\u00e7\u00e3o da amostra, sendo a agulha 26s-22 a mais adequada para uso em cromatografia gasosa no espa\u00e7ador de amostragem; a agulha de ponta plana, usada principalmente em cromat\u00f3grafos l\u00edquidos de alto desempenho, na v\u00e1lvula de inje\u00e7\u00e3o e no tubo de suc\u00e7\u00e3o da amostra. A agulha de ponta plana \u00e9 usada principalmente para a v\u00e1lvula de inje\u00e7\u00e3o e o tubo de suc\u00e7\u00e3o de amostra do HPLC.<\/p>\n<p>M\u00e9todos de amostragem<\/p>\n<p>De acordo com o m\u00e9todo de alimenta\u00e7\u00e3o, pode ser dividida em agulha de inje\u00e7\u00e3o autom\u00e1tica e agulha de inje\u00e7\u00e3o manual. De acordo com a agulha no cromat\u00f3grafo a g\u00e1s, o l\u00edquido do cromat\u00f3grafo l\u00edquido em diferentes requisitos anal\u00edticos pode ser dividido em agulha de inje\u00e7\u00e3o de fase gasosa e agulha de inje\u00e7\u00e3o de fase l\u00edquida. A agulha de inje\u00e7\u00e3o de cromatografia gasosa geralmente precisa alimentar um pouco menos, o volume de inje\u00e7\u00e3o mais comum \u00e9 de 0,2-1ul, portanto, a sele\u00e7\u00e3o correspondente da agulha de inje\u00e7\u00e3o geralmente \u00e9 de 10-25ul. A sele\u00e7\u00e3o da agulha para o tipo de cone de agulha facilita a alimenta\u00e7\u00e3o da opera\u00e7\u00e3o da amostra;<\/p>\n<p>Por outro lado, o volume de inje\u00e7\u00e3o da cromatografia l\u00edquida \u00e9 geralmente maior, com volume de inje\u00e7\u00e3o comum de 0,5 a 20 ul, de modo que o volume relativo da agulha tamb\u00e9m \u00e9 maior, geralmente de 25 a 100 ul, e a ponta da agulha \u00e9 plana, para evitar arranh\u00f5es no estator.<\/p>\n<p>Na an\u00e1lise cromatogr\u00e1fica, a agulha de inje\u00e7\u00e3o mais comumente usada para agulha de microamostragem, especialmente adequada para cromatografia gasosa e cromatografia l\u00edquida para an\u00e1lise. Seu erro de capacidade total \u00e9 de \u00b1 5%. A estanqueidade ao g\u00e1s pode suportar 0,2 mpa. Ele \u00e9 dividido em dois tipos de injetores sem armazenamento de l\u00edquido e com armazenamento de l\u00edquido. A faixa de especifica\u00e7\u00e3o do microamostrador de l\u00edquido n\u00e3o armazenado \u00e9 de 0,5\u03bcL-5\u03bcL, e a faixa de especifica\u00e7\u00e3o do microamostrador de l\u00edquido armazenado \u00e9 de 10\u03bcL-100\u03bcL. A agulha de microamostragem \u00e9 um tipo de instrumento de precis\u00e3o indispens\u00e1vel.<\/p>\n<p>Uso da agulha de inje\u00e7\u00e3o<\/p>\n<p>1, verifique o alimentador antes do uso, verifique se h\u00e1 rachaduras no cilindro e se a ponta da agulha est\u00e1 peluda. 2, exclua a amostra residual no alimentador, lave o alimentador com solvente de 5 a 20 vezes e descarte o l\u00edquido residual das primeiras 2 a 3 vezes. 3, exclua as bolhas de ar no alimentador, mergulhe a ponta da agulha no solvente e retire a amostra repetidamente. Quando a amostra \u00e9 exclu\u00edda, as bolhas no alimentador podem mudar com a mudan\u00e7a vertical do tubo.4. Ao usar o alimentador, primeiro sugue o alimentador cheio de l\u00edquido e, em seguida, exclua o l\u00edquido at\u00e9 o volume desejado da amostra.<\/p>\n<p>Manuten\u00e7\u00e3o do \u00eambolo<\/p>\n<p>&nbsp;<\/p>\n<p>1, n\u00e3o pode for\u00e7ar o \u00eambolo. 2, quando a agulha est\u00e1 bloqueada, n\u00e3o \u00e9 poss\u00edvel for\u00e7ar o \u00eambolo, pois a alta press\u00e3o pode causar a ruptura do tambor do \u00eambolo. 3, o \u00eambolo do amostrador padr\u00e3o n\u00e3o pode ser trocado, cada \u00eambolo \u00e9 adequado para o amostrador correspondente na camada aderente. 4, quando o alimentador estiver seco, na medida do poss\u00edvel, n\u00e3o bombeie o \u00eambolo. 5, limpe o \u00eambolo com um tecido sem rebarbas e n\u00e3o o dobre. 6, o \u00eambolo pode ser usado para limpar o \u00eambolo. 7, o \u00eambolo deve ser usado para limpar o \u00eambolo, n\u00e3o para dobrar. 8, o \u00eambolo n\u00e3o pode ser usado para limpar o \u00eambolo. 9, o \u00eambolo n\u00e3o pode ser usado para limpar o \u00eambolo.<\/p>\n<p>Manuten\u00e7\u00e3o da agulha<\/p>\n<p>1, as amostras de m\u00e9dia a alta viscosidade devem ser dilu\u00eddas antes do uso ou selecionar um di\u00e2metro interno grande para a agulha de inje\u00e7\u00e3o. 2, a agulha de limpeza deve ser usada ao limpar as ferramentas, como o fio do tubo ou a agulha do n\u00facleo do tubo, pin\u00e7as, subst\u00e2ncias tensoativas usadas para limpar a parede da agulha. 3, limpeza t\u00e9rmica, limpeza t\u00e9rmica para remover res\u00edduos org\u00e2nicos na agulha, especialmente para an\u00e1lise de tra\u00e7os, alto ponto de ebuli\u00e7\u00e3o e subst\u00e2ncias viscosas. Ap\u00f3s alguns minutos de limpeza t\u00e9rmica, a ferramenta de limpeza da agulha pode ser usada novamente.<\/p>\n<p>Limpeza da agulha<\/p>\n<p>1, voc\u00ea pode usar solventes org\u00e2nicos para limpar a parede interna da agulha; ao limpar, preste aten\u00e7\u00e3o para verificar se o empurrador da agulha pode se mover suavemente; 2, se o empurrador da agulha n\u00e3o se mover suavemente, voc\u00ea pode remover o empurrador. Recomenda-se usar um pano macio embebido em solvente org\u00e2nico para limp\u00e1-lo. 3, repita o uso de suc\u00e7\u00e3o com solvente org\u00e2nico se, ap\u00f3s algumas vezes de suc\u00e7\u00e3o, a resist\u00eancia do empurrador da agulha aumentar muito rapidamente, ou seja, ainda houver alguma sujeira pequena, o que ocorre depois que o processo de limpeza precisa ser repetido. 4, se o empurrador da agulha puder se movimentar de forma fluente e suave, verifique se a agulha est\u00e1 entupida. Repita o enx\u00e1gue da agulha com solvente org\u00e2nico para verificar o formato da amostra que est\u00e1 sendo empurrada para fora da agulha. 5, se a agulha estiver normal, a amostra fluir\u00e1 em linha reta; se a agulha estiver entupida, a amostra ser\u00e1 pulverizada em uma dire\u00e7\u00e3o ou em um \u00e2ngulo na forma de uma n\u00e9voa fina. Mesmo que o solvente \u00e0s vezes flua em linha reta, verifique cuidadosamente se o fluxo \u00e9 melhor do que o normal (basta comparar o fluxo com uma agulha nova e desentupida). 6. O entupimento da agulha pode destruir a reprodutibilidade da an\u00e1lise e, por esse motivo, a manuten\u00e7\u00e3o da agulha \u00e9 essencial. Remova qualquer entupimento da agulha com, por exemplo, um fio de metal. A agulha s\u00f3 deve ser usada se a amostra fluir normalmente. O uso de uma pipeta para aspirar ou de um limpador de seringa tamb\u00e9m pode ser eficaz na remo\u00e7\u00e3o de contaminantes da seringa.<\/p>\n<p>Precau\u00e7\u00f5es para o uso da agulha de inje\u00e7\u00e3o<\/p>\n<p>A m\u00e3o n\u00e3o pega a agulha da seringa e tem partes da amostra, n\u00e3o tem bolhas de ar, a suc\u00e7\u00e3o da amostra deve ser lenta, descarga r\u00e1pida e, em seguida, suc\u00e7\u00e3o lenta, repetida algumas vezes, parte da agulha de metal da seringa de 10 \u03bcl do volume de 0.6 \u03bcl, n\u00e3o \u00e9 poss\u00edvel ver bolhas, mais suc\u00e7\u00e3o de 1-2 \u03bcl para a ponta da seringa em dire\u00e7\u00e3o \u00e0s bolhas superiores na parte superior da seringa e, em seguida, empurre a barra da agulha para excluir as bolhas de ar (refere-se \u00e0 seringa de 10 \u03bcl, com uma sensa\u00e7\u00e3o plana da seringa central) na velocidade da amostra deve ser r\u00e1pida (mas n\u00e3o \u00e9 f\u00e1cil de ser r\u00e1pida), cada vez que a amostra mantiver a mesma velocidade, a ponta da agulha para o meio da c\u00e2mara de vaporiza\u00e7\u00e3o para come\u00e7ar a injetar a amostra.<\/p>\n<p>Perguntas frequentes sobre a agulha de inje\u00e7\u00e3o<\/p>\n<h2><strong>1\u3001Como evitar que a agulha de inje\u00e7\u00e3o se dobre?<\/strong><\/h2>\n<p><!-- lc-qa-start --><\/p>\n<p><strong>Quick answer:<\/strong> For general industrial-chemical topics, the safest commercial decision usually comes from checking application fit, specification, process compatibility, and handling requirements together instead of relying on one simplified rule.<\/p>\n<p><!-- lc-qa-end --><\/p>\n<p>Resposta: Muitos cromat\u00f3grafos iniciantes costumam entortar a agulha e a haste da seringa, e os motivos s\u00e3o os seguintes:<\/p>\n<p>(1) A porta de entrada est\u00e1 muito apertada, a temperatura ambiente est\u00e1 muito apertada quando a temperatura da c\u00e2mara de vaporiza\u00e7\u00e3o fica mais apertada, quando a temperatura aumenta ap\u00f3s a expans\u00e3o da gaxeta de s\u00edlica gel, \u00e9 dif\u00edcil amarrar a seringa.<\/p>\n<p>(2) A localiza\u00e7\u00e3o da agulha n\u00e3o \u00e9 boa para encontrar a parte met\u00e1lica da entrada da amostra.<\/p>\n<p>(3) A haste da seringa est\u00e1 dobrada, pois \u00e9 muito forte ao alimentar a amostra, a cromatografia importada com um rack de alimenta\u00e7\u00e3o, alimentar a amostra com um rack de alimenta\u00e7\u00e3o n\u00e3o dobrar\u00e1 a haste da seringa.<\/p>\n<p>(4) Como a parede interna da seringa est\u00e1 contaminada, a barra da agulha \u00e9 for\u00e7ada a se dobrar durante a inje\u00e7\u00e3o. Ap\u00f3s um per\u00edodo de tempo, a seringa ser\u00e1 encontrada perto da parte superior de uma pequena se\u00e7\u00e3o de material preto e, nesse momento, a inje\u00e7\u00e3o por suc\u00e7\u00e3o parecer\u00e1 extenuante. O m\u00e9todo de limpeza ser\u00e1 retirar a barra da agulha, injetar um pouco de \u00e1gua, inserir a barra da agulha na posi\u00e7\u00e3o da contamina\u00e7\u00e3o, empurrar e puxar repetidamente, n\u00e3o se pode injetar na \u00e1gua at\u00e9 que os poluentes sejam eliminados, ent\u00e3o voc\u00ea ver\u00e1 que a \u00e1gua dentro da seringa fica turva, a barra da agulha \u00e9 retirada com um papel de filtro para limp\u00e1-la e depois lavada com \u00e1lcool algumas vezes. An\u00e1lise da amostra para amostras s\u00f3lidas dissolvidas por solvente, na amostra a tempo de lavar a seringa com solvente.<\/p>\n<p>(5) a amostra deve estar est\u00e1vel; se voc\u00ea for r\u00e1pido demais, a seringa se dobrar\u00e1, desde que a amostra seja naturalmente r\u00e1pida.<\/p>\n<h2><strong>2. nas TIPs de habilidades com agulhas?<\/strong><\/h2>\n<p>(1) se a agulha na almofada de amostra estiver mais apertada, injete a amostra depois que a agulha for puxada rapidamente; se a agulha na almofada de amostra estiver solta, injete a amostra depois que a agulha for mais lenta.<\/p>\n<p>(2) Retire imediatamente. O volume da amostra deve ser pequeno para garantir que o formato do pico seja bom. Observe que o amostrador n\u00e3o deixa bolhas de ar, suc\u00e7\u00e3o lenta, batida r\u00e1pida, as bolhas de ar saem;<\/p>\n<p>(3) mais suc\u00e7\u00e3o algumas vezes antes da amostra para esgotar as bolhas de ar, entrada e sa\u00edda r\u00e1pidas da amostra, a agulha na posi\u00e7\u00e3o para ir o mais longe poss\u00edvel para fixar a posi\u00e7\u00e3o, quanto \u00e0 amostra ap\u00f3s o tempo de in\u00edcio, n\u00e3o precisa ser particularmente r\u00e1pida, desde que para garantir que cada vez que voc\u00ea amarrar o final do intervalo de tempo de acordo com o in\u00edcio possa ser consistente;<\/p>\n<p>(4) geralmente para ser retirado imediatamente, h\u00e1 um ditado que diz que a agulha na almofada de amostragem reduzir\u00e1 a veda\u00e7\u00e3o da introdu\u00e7\u00e3o de algumas impurezas do ar, de acordo com a an\u00e1lise de diferentes amostras, a amostragem lenta tamb\u00e9m causar\u00e1 arrastamento da cauda, Al\u00e9m do mesmo lote de amostras, \u00e9 melhor entrar na mesma pessoa para garantir que a amostragem da reprodutibilidade da amostragem de diferentes pessoas no erro de amostragem ser\u00e1 uma grande diferen\u00e7a, de acordo com os engenheiros da agilent, pode garantir que a taxa de erro de 5% ou menos, mesmo que seja relativamente boa, as agulhas de amostragem originais s\u00e3o muito caras, tenha cuidado. H\u00e1 tamb\u00e9m um ditado que diz que a amostra pode ser retirada imediatamente ap\u00f3s a inje\u00e7\u00e3o, o que pode desempenhar um papel semelhante ao da agita\u00e7\u00e3o, no injetor, para tornar a vaporiza\u00e7\u00e3o da amostra mais uniforme e reduzir o efeito de discrimina\u00e7\u00e3o de deriva\u00e7\u00e3o.<\/p>\n<p>(5) A solu\u00e7\u00e3o a ser medida deve estar contida em um frasco de inje\u00e7\u00e3o vedado (alguns precisam ser armazenados ao abrigo da luz), de modo a n\u00e3o volatilizar o solvente, resultando em uma altera\u00e7\u00e3o na concentra\u00e7\u00e3o da solu\u00e7\u00e3o entre duas inje\u00e7\u00f5es.<\/p>\n<p>(6) Antes de injetar a amostra, a agulha de inje\u00e7\u00e3o deve ser lavada com solvente cerca de tr\u00eas vezes para garantir que n\u00e3o haja res\u00edduos da \u00faltima inje\u00e7\u00e3o. Lave a agulha de inje\u00e7\u00e3o com a solu\u00e7\u00e3o a ser medida cerca de tr\u00eas vezes para garantir que a concentra\u00e7\u00e3o da amostra e a concentra\u00e7\u00e3o da solu\u00e7\u00e3o a ser medida sejam as mesmas.<\/p>\n<p>(7) Preste aten\u00e7\u00e3o para eliminar as bolhas de ar na agulha de inje\u00e7\u00e3o, de modo a evitar desvios entre o volume real de inje\u00e7\u00e3o e o valor rotulado. As t\u00e9cnicas de amostragem devem ser consistentes e r\u00e1pidas.<\/p>\n<p>(8) O anel de borracha deve ser verificado diligentemente para evitar o envelhecimento.<\/p>\n<p>(9) a agulha deve estar alinhada com o centro do orif\u00edcio do amostrador, para evitar que a agulha entre no cateter do amostrador.<\/p>\n<h2><strong>3. fazer experimentos de fase l\u00edquida na agulha foi oxidado adstringente, afetando a amostragem, como lidar com isso?<\/strong><\/h2>\n<p>(1) a maioria das pessoas recomenda o enx\u00e1gue com metanol, 20 minutos de ultrassom e, em seguida, o uso de metanol puro para tentar o ultrassom. Em geral, recomenda-se o uso de metanol ap\u00f3s a limpeza com \u00e1gua e, em seguida, a lavagem com metanol puro, para que a agulha n\u00e3o fique adstringente.<\/p>\n<p>(2) tamb\u00e9m pode ser usada a lavagem com \u00e1cido n\u00edtrico dilu\u00eddo 5%, pois a amostra \u00e0s vezes n\u00e3o \u00e9 metanol puro dissolvido em metanol e \u00e1gua, de modo que a parte de ferro da agulha de alimenta\u00e7\u00e3o na ferrugem, com a lavagem com \u00e1cido n\u00edtrico dilu\u00eddo, pode remover a ferrugem.<\/p>\n<p><!-- lc-commercial-start --><\/p>\n<h2>How technical buyers usually evaluate this chemical topic<\/h2>\n<p>General chemical decisions usually become clearer when teams move from theory to application fit: what the material needs to do, how pure it needs to be, how it behaves in the real process, and what downstream constraints it must satisfy.<\/p>\n<ul>\n<li><strong>Define the use case first:<\/strong> laboratory understanding and industrial purchasing often need different levels of specification detail.<\/li>\n<li><strong>Check process compatibility:<\/strong> handling, blending, stability, and downstream interaction often determine whether a material is practical to use.<\/li>\n<li><strong>Review storage and transport behavior:<\/strong> shelf life, moisture sensitivity, temperature range, and packaging can all matter commercially.<\/li>\n<li><strong>Use sample validation when the application is critical:<\/strong> small-scale confirmation often saves the most time before a full purchasing decision.<\/li>\n<\/ul>\n<h3>Recommended product references<\/h3>\n<ul>\n<li><strong><a href=\"https:\/\/longchangchemical.com\/pt\/product\/chlumiaf-094\/\">CHLUMIAF 094<\/a>:<\/strong> A balanced defoamer reference for waterborne coatings and many general foam-control screens.<\/li>\n<li><strong><a href=\"https:\/\/longchangchemical.com\/pt\/product\/chlumiaf-3062\/\">CHLUMIAF 3062<\/a>:<\/strong> Useful when printing-ink and UV-ink compatibility matter in the defoaming screen.<\/li>\n<li><strong><a href=\"https:\/\/longchangchemical.com\/pt\/product\/chlumiaf-3037\/\">CHLUMIAF 3037<\/a>:<\/strong> A stronger process-defoaming option when persistent foam survives harsher conditions.<\/li>\n<li><strong><a href=\"https:\/\/longchangchemical.com\/pt\/product\/chlumiwe-3280\/\">CHLUMIWE 3280<\/a>:<\/strong> A strong wetting-agent reference for inks, coatings, and difficult substrate wetting.<\/li>\n<\/ul>\n<h3>FAQ for buyers and formulators<\/h3>\n<p><strong>Why can a material that looks correct on paper still underperform in use?<\/strong><br \/>Because real-world process conditions, substrate interaction, and storage behavior can reveal problems that are not obvious in a simplified specification review.<\/p>\n<p><strong>Should technical chemical selection always start with the lowest-cost option?<\/strong><br \/>Not usually. The lowest purchase price is not always the lowest use cost once process fit, stability, and downstream quality are considered.<\/p>\n<p><!-- lc-commercial-end --><\/p>","protected":false},"excerpt":{"rendered":"<p>Chromatographic injection needle is small but indispensable, the injection needle is connected to the sample and analytical instrument channels, with the injection needle, the sample can enter the chromatographic column,<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[106],"tags":[],"class_list":["post-6555","post","type-post","status-publish","format-standard","hentry","category-laboratory-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What are some tips for using a chromatography injection needle? - Longchang Chemical<\/title>\n<meta name=\"description\" content=\"Chromatographic injection needle is small but indispensable, the injection needle is connected to the sample and analytical instrument channels, with th...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longchangchemical.com\/pt\/what-are-some-tips-for-using-a-chromatography-injection-needle\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What are some tips for using a chromatography injection needle? - Longchang Chemical\" \/>\n<meta property=\"og:description\" content=\"Chromatographic injection needle is small but indispensable, the injection needle is connected to the sample and analytical instrument channels, with th...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longchangchemical.com\/pt\/what-are-some-tips-for-using-a-chromatography-injection-needle\/\" \/>\n<meta property=\"og:site_name\" content=\"Longchang Chemical\" \/>\n<meta property=\"article:published_time\" content=\"2024-01-24T05:57:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-28T10:42:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2024\/02\/logo-jpeg.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Longchang Chemical\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/\"},\"author\":{\"name\":\"Longchang Chemical\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e\"},\"headline\":\"What are some tips for using a chromatography injection needle?\",\"datePublished\":\"2024-01-24T05:57:06+00:00\",\"dateModified\":\"2026-04-28T10:42:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/\"},\"wordCount\":2285,\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"articleSection\":[\"Laboratory News\"],\"inLanguage\":\"pt-BR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/\",\"url\":\"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/\",\"name\":\"What are some tips for using a chromatography injection needle? - Longchang Chemical\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/#website\"},\"datePublished\":\"2024-01-24T05:57:06+00:00\",\"dateModified\":\"2026-04-28T10:42:24+00:00\",\"description\":\"Chromatographic injection needle is small but indispensable, the injection needle is connected to the sample and analytical instrument channels, with th...\",\"breadcrumb\":{\"@id\":\"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/longchangchemical.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What are some tips for using a chromatography injection needle?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/longchangchemical.com\/#website\",\"url\":\"https:\/\/longchangchemical.com\/\",\"name\":\"Longchang Chemical\",\"description\":\"China chemical manufacturer \uff06 supplier\",\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/longchangchemical.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/longchangchemical.com\/#organization\",\"name\":\"Longchang Chemical\",\"url\":\"https:\/\/longchangchemical.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"contentUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"width\":512,\"height\":512,\"caption\":\"Longchang Chemical\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e\",\"name\":\"Longchang Chemical\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g\",\"caption\":\"Longchang Chemical\"},\"sameAs\":[\"https:\/\/longchangchemical.com\"],\"url\":\"https:\/\/longchangchemical.com\/pt\/author\/infolongchangchemical-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Quais s\u00e3o algumas dicas para usar uma agulha de inje\u00e7\u00e3o cromatogr\u00e1fica? - Qu\u00edmica Longchang","description":"Chromatographic injection needle is small but indispensable, the injection needle is connected to the sample and analytical instrument channels, with th...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longchangchemical.com\/pt\/what-are-some-tips-for-using-a-chromatography-injection-needle\/","og_locale":"pt_BR","og_type":"article","og_title":"What are some tips for using a chromatography injection needle? - Longchang Chemical","og_description":"Chromatographic injection needle is small but indispensable, the injection needle is connected to the sample and analytical instrument channels, with th...","og_url":"https:\/\/longchangchemical.com\/pt\/what-are-some-tips-for-using-a-chromatography-injection-needle\/","og_site_name":"Longchang Chemical","article_published_time":"2024-01-24T05:57:06+00:00","article_modified_time":"2026-04-28T10:42:24+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2024\/02\/logo-jpeg.jpg","type":"image\/jpeg"}],"author":"Longchang Chemical","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/#article","isPartOf":{"@id":"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/"},"author":{"name":"Longchang Chemical","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e"},"headline":"What are some tips for using a chromatography injection needle?","datePublished":"2024-01-24T05:57:06+00:00","dateModified":"2026-04-28T10:42:24+00:00","mainEntityOfPage":{"@id":"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/"},"wordCount":2285,"publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"articleSection":["Laboratory News"],"inLanguage":"pt-BR"},{"@type":"WebPage","@id":"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/","url":"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/","name":"Quais s\u00e3o algumas dicas para usar uma agulha de inje\u00e7\u00e3o cromatogr\u00e1fica? - Qu\u00edmica Longchang","isPartOf":{"@id":"https:\/\/longchangchemical.com\/#website"},"datePublished":"2024-01-24T05:57:06+00:00","dateModified":"2026-04-28T10:42:24+00:00","description":"Chromatographic injection needle is small but indispensable, the injection needle is connected to the sample and analytical instrument channels, with th...","breadcrumb":{"@id":"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longchangchemical.com\/what-are-some-tips-for-using-a-chromatography-injection-needle\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/longchangchemical.com\/"},{"@type":"ListItem","position":2,"name":"What are some tips for using a chromatography injection needle?"}]},{"@type":"WebSite","@id":"https:\/\/longchangchemical.com\/#website","url":"https:\/\/longchangchemical.com\/","name":"Qu\u00edmica Longchang","description":"Fabricante de produtos qu\u00edmicos na China \uff06 fornecedor","publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longchangchemical.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/longchangchemical.com\/#organization","name":"Qu\u00edmica Longchang","url":"https:\/\/longchangchemical.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/","url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","contentUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","width":512,"height":512,"caption":"Longchang Chemical"},"image":{"@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e","name":"Qu\u00edmica Longchang","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g","caption":"Longchang Chemical"},"sameAs":["https:\/\/longchangchemical.com"],"url":"https:\/\/longchangchemical.com\/pt\/author\/infolongchangchemical-com\/"}]}},"_links":{"self":[{"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/posts\/6555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/comments?post=6555"}],"version-history":[{"count":5,"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/posts\/6555\/revisions"}],"predecessor-version":[{"id":9769,"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/posts\/6555\/revisions\/9769"}],"wp:attachment":[{"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/media?parent=6555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/categories?post=6555"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/longchangchemical.com\/pt\/wp-json\/wp\/v2\/tags?post=6555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}