{"id":7830,"date":"2025-01-06T10:57:04","date_gmt":"2025-01-06T10:57:04","guid":{"rendered":"https:\/\/longchangchemical.com\/?p=7830"},"modified":"2026-04-28T09:55:32","modified_gmt":"2026-04-28T09:55:32","slug":"what-are-the-ratios-of-commonly-used-chemicals","status":"publish","type":"post","link":"https:\/\/longchangchemical.com\/it\/what-are-the-ratios-of-commonly-used-chemicals\/","title":{"rendered":"Quali sono i rapporti tra le sostanze chimiche e le tecniche operative comunemente utilizzate negli impianti di trattamento delle acque reflue?"},"content":{"rendered":"<p><!-- lc-qa-start --><\/p>\n<p><strong>Risposta rapida:<\/strong> For sewage, biochemical, and wastewater-treatment topics, operators usually move fastest when they review the process stage, water quality data, and control objective together rather than chasing one symptom alone.<\/p>\n<p><!-- lc-qa-end --><\/p>\n<p>Un impianto di trattamento delle acque reflue deve aggiungere varie sostanze chimiche durante il processo di trattamento per garantire che la qualit\u00e0 dell'effluente sia conforme agli standard. I prodotti chimici comunemente utilizzati includono coagulanti, flocculanti, fonti di carbonio, ecc. Questo articolo presenter\u00e0 i rapporti di dosaggio, gli indicatori tecnici e le tecniche di funzionamento pratico di questi prodotti chimici. Nell'uso effettivo, le regolazioni devono essere effettuate in base alla qualit\u00e0 dell'acqua e agli obiettivi di trattamento specifici e il dosaggio ottimale pu\u00f2 essere determinato attraverso esperimenti.<\/p>\n<p><strong>Rapporto di dosaggio del coagulante<\/strong><\/p>\n<p>I coagulanti sono utilizzati principalmente per rimuovere i solidi sospesi e le particelle colloidali nelle acque reflue. I coagulanti pi\u00f9 comunemente utilizzati sono il solfato di alluminio, il cloruro di polialluminio (PAC) e il cloruro ferrico.<\/p>\n<p><b>1. Solfato di alluminio<\/b><\/p>\n<p>Ambito di applicazione: adatto per acque reflue con pH elevato e alta alcalinit\u00e0.<\/p>\n<p>Rapporto di dosaggio: generalmente 50-150 mg\/L.<\/p>\n<p>Indice tecnico: il contenuto del principio attivo del solfato di alluminio Al2O3 deve essere superiore a 15%.<\/p>\n<p>Consigli per l'uso: Il solfato di alluminio deve essere completamente sciolto prima dell'uso e il tempo di dissoluzione \u00e8 di circa 30 minuti. La concentrazione generale di dissoluzione \u00e8 5-10%.<\/p>\n<p>Esempio: Un impianto di trattamento delle acque reflue con una capacit\u00e0 di trattamento di 1000 m\u00b3\/h e un pH dell'acqua grezza di 7,5 deve aggiungere solfato di alluminio. In base all'esperienza, il dosaggio \u00e8 di 100 mg\/L, il che significa che \u00e8 necessario aggiungere 100 kg di solfato di alluminio all'ora.<\/p>\n<p><strong>2. Cloruro di polialluminio (PAC)<\/strong><\/p>\n<p>Ambito di applicazione: Adatto per acque reflue con diversi valori di pH, in particolare per acque reflue ad alta torbidit\u00e0.<\/p>\n<p>Rapporto di dosaggio: Generalmente 10-50 mg\/L.<\/p>\n<p>Indice tecnico: L'alcalinit\u00e0 del PAC deve essere compresa tra 50-80%.<\/p>\n<p>Consigli per l'uso: Il PAC deve essere completamente sciolto prima dell'uso e il tempo di dissoluzione \u00e8 di circa 30 minuti. La concentrazione generale di dissoluzione \u00e8 5-10%.<\/p>\n<p>Esempio: Un impianto di trattamento delle acque reflue con una capacit\u00e0 di 500 m\u00b3\/h e un'elevata torbidit\u00e0 dell'acqua grezza deve aggiungere PAC. In base all'esperienza, il dosaggio \u00e8 di 30 mg\/L, il che significa che \u00e8 necessario aggiungere 15 kg di PAC all'ora.<\/p>\n<p>La concentrazione effettiva deve essere regolata in base alla qualit\u00e0 dell'acqua e agli obiettivi di trattamento specifici, e il dosaggio ottimale pu\u00f2 essere determinato attraverso la sperimentazione.<\/p>\n<p>Concentrazione tipica del dosaggio: La concentrazione tipica di dosaggio del cloruro di polialluminio \u00e8 10%-16%. Ci\u00f2 significa che 10-16 kg di polvere secca di PAC sono contenuti in 100 kg di soluzione di PAC. Questa concentrazione si riferisce alla concentrazione della soluzione chimica, non direttamente correlata al volume di acqua.<\/p>\n<p><strong>Dosaggio<\/strong><\/p>\n<p>Il dosaggio per tonnellata di acque reflue: Il dosaggio del cloruro di polialluminio \u00e8 di circa 0,5-2 kg di polvere di PAC secca per tonnellata di acque reflue. Il dosaggio viene determinato in base alle caratteristiche delle acque reflue e ai requisiti di trattamento. L'uso effettivo deve essere regolato in base alla qualit\u00e0 dell'acqua e agli obiettivi di trattamento specifici.<\/p>\n<p>Dosaggio per le diverse qualit\u00e0 dell'acqua: Il dosaggio del PAC varia a seconda delle condizioni di qualit\u00e0 dell'acqua. Ecco alcuni valori di riferimento:<\/p>\n<p>Acqua domestica: 2,5-25 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acqua industriale: 2,5-25 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acque reflue comunali: 15-50 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acque reflue di galvanizzazione: 20-100 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acque reflue metallurgiche: 20-150 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acque reflue di produzione della carta: 50-300 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acque reflue di concia: 100-300 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acqua di scarto alimentare: 50-150 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acque reflue chimiche: 50-100 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acque reflue di emulsificazione: 50-200 kg\/1.000 tonnellate di acqua<\/p>\n<p>Acque reflue di lavaggio del carbone: 30-100 kg\/1.000 tonnellate di acqua<\/p>\n<p>Queste cifre forniscono un rapporto e un dosaggio approssimativo dei diversi prodotti chimici per tonnellata di acqua trattata. L'uso effettivo deve essere regolato in base alla qualit\u00e0 dell'acqua e agli obiettivi di trattamento specifici e il dosaggio ottimale pu\u00f2 essere determinato attraverso la sperimentazione.<\/p>\n<p><b>3. Cloruro ferrico<\/b><\/p>\n<p>Ambito di applicazione: adatto alle acque reflue contenenti ioni di metalli pesanti.<\/p>\n<p>Rapporto di dosaggio: generalmente 10-50 mg\/L.<\/p>\n<p>Indice tecnico: il contenuto del principio attivo Fe2O3 nel cloruro ferrico deve essere superiore a 30%.<\/p>\n<p>Consigli per l'uso: Il cloruro ferrico deve essere completamente sciolto prima dell'uso, con un tempo di dissoluzione di circa 30 minuti e una concentrazione generale di dissoluzione di 5-10%.<\/p>\n<p>Esempio: Un impianto di trattamento delle acque reflue industriali con una capacit\u00e0 di trattamento di 200 m\u00b3\/h deve rimuovere gli ioni di metalli pesanti e deve aggiungere cloruro ferrico. In base all'esperienza, il dosaggio \u00e8 di 20 mg\/L, il che significa che \u00e8 necessario aggiungere 4 kg di cloruro ferrico all'ora.<\/p>\n<p><strong>Rapporto di dosaggio del flocculante<\/strong><\/p>\n<p>I flocculanti sono utilizzati principalmente per migliorare l'effetto di coagulazione. I flocculanti comunemente utilizzati sono la poliacrilammide (PAM), ecc.<\/p>\n<p><b>1. Poliacrilammide (PAM)<\/b><\/p>\n<p>Ambito di applicazione: adatto al trattamento di flocculazione di varie acque reflue.<\/p>\n<p>Rapporto di dosaggio: generalmente 0,1-0,5 mg\/L.<\/p>\n<p>Indice tecnico: il peso molecolare del PAM deve essere superiore a 10 milioni.<\/p>\n<p>Tecnica operativa: La PAM deve essere completamente sciolta prima dell'uso e il tempo di dissoluzione \u00e8 di circa 60 minuti. La concentrazione generale di dissoluzione \u00e8 0,1-0,5%.<\/p>\n<p>Esempio: Un impianto di trattamento delle acque reflue con una capacit\u00e0 di trattamento di 1000 m\u00b3\/h deve aggiungere PAM. Secondo l'esperienza, il dosaggio \u00e8 di 0,3 mg\/L, quindi \u00e8 necessario aggiungere 0,3 kg di PAM all'ora.<\/p>\n<p><strong>Rapporto di dosaggio delle sostanze chimiche della fonte di carbonio<\/strong><\/p>\n<p>Le sostanze chimiche di origine carbonica sono utilizzate principalmente nel processo di rimozione biologica dell'azoto. Le sostanze chimiche di origine carbonica comunemente utilizzate sono metanolo, etanolo, acido acetico, ecc.<\/p>\n<p><b>1. Metanolo<\/b><\/p>\n<p>Ambito di applicazione: adatto ai processi di denitrificazione e rimozione dell'azoto.<\/p>\n<p>Rapporto di dosaggio: generalmente 3 mg\/L (per ogni 1 mg\/L di nitrato rimosso).<\/p>\n<p>Indice tecnico: la purezza del metanolo deve essere superiore a 99%.<\/p>\n<p>Suggerimenti operativi: Il metanolo deve essere aggiunto direttamente alla sezione anossica e mescolato accuratamente con l'affluente e il liquido miscelato dal miscelatore.<\/p>\n<p>Esempio: Un impianto di depurazione con una capacit\u00e0 di trattamento di 1000 m\u00b3\/h deve rimuovere 20 mg\/L di azoto nitrico e deve aggiungere metanolo. In base all'esperienza, il dosaggio \u00e8 di 60 mg\/L, il che richiede l'aggiunta di 60 kg di metanolo all'ora.<\/p>\n<p><strong>Consigli pratici per l'uso<\/strong><\/p>\n<p><strong>1. Sciogliere e conservare i prodotti chimici<\/strong><\/p>\n<p>I prodotti chimici devono essere completamente sciolti prima dell'uso e il tempo di dissoluzione e la concentrazione devono essere determinati in base alle caratteristiche specifiche del prodotto chimico. I prodotti chimici devono essere conservati in un luogo asciutto, fresco e ben ventilato, lontano dalla luce solare diretta e dalle alte temperature.<\/p>\n<p><b>2. Selezione dei punti di dosaggio<\/b><\/p>\n<p>Il punto di dosaggio dei prodotti chimici deve essere scelto in un luogo con un forte flusso d'acqua turbolento, per garantire che i prodotti chimici si diffondano rapidamente e uniformemente. Per i processi di trattamento a pi\u00f9 stadi, le sostanze chimiche devono essere dosate in fasi successive per migliorare l'effetto del trattamento.<\/p>\n<p><strong>3. Apparecchiature di dosaggio<\/strong><\/p>\n<p>Per garantire l'accuratezza del dosaggio, \u00e8 necessario scegliere una pompa dosatrice. L'apparecchiatura di dosaggio deve essere sottoposta a regolare manutenzione per garantirne il normale funzionamento.<\/p>\n<p><b>4. Monitoraggio e controllo online<\/b><\/p>\n<p>\u00c8 necessario installare un sistema di monitoraggio online per controllare la qualit\u00e0 dell'acqua in ingresso e in uscita in tempo reale e regolare il dosaggio dei prodotti chimici in modo tempestivo. Dovrebbe essere installato un sistema di controllo automatico per regolare automaticamente il dosaggio dei prodotti chimici in base alle variazioni della qualit\u00e0 dell'acqua, per garantire che la qualit\u00e0 dell'acqua in uscita soddisfi stabilmente gli standard.<\/p>\n<p>Selezionando e dosando in modo ragionevole i prodotti chimici, l'impianto di depurazione pu\u00f2 rimuovere efficacemente gli inquinanti presenti nelle acque reflue e garantire che la qualit\u00e0 degli effluenti sia conforme agli standard. Allo stesso tempo, ottimizzando il processo di dosaggio e le attrezzature, \u00e8 possibile migliorare l'efficienza del trattamento e ridurre i costi operativi.<\/p>\n<p>Il rapporto di dosaggio dei vari prodotti chimici deve essere determinato in base alla qualit\u00e0 specifica dell'acqua e ai risultati sperimentali per ottenere i migliori risultati di trattamento.<\/p>\n<p><!-- lc-commercial-start --><\/p>\n<h2>How technical buyers and operators usually evaluate wastewater-treatment issues<\/h2>\n<p>Most wastewater-treatment problems are system problems. Teams usually get a better result when they define the process stage and water-quality target first, then review biological, chemical, and operational factors together before making a plant-scale correction.<\/p>\n<ul>\n<li><strong>Start from the process stage:<\/strong> pretreatment, biological treatment, sludge handling, and polishing steps can point to very different root causes.<\/li>\n<li><strong>Check the core water-quality data together:<\/strong> pH, COD, nitrogen, salinity, sludge condition, and dissolved oxygen often need to be read as one picture.<\/li>\n<li><strong>Review compliance and operability at the same time:<\/strong> the quickest local fix can still be the wrong commercial move if it destabilizes another part of the plant.<\/li>\n<li><strong>Use pilot or staged validation where possible:<\/strong> wastewater systems often respond differently at scale than they do in simplified bench assumptions.<\/li>\n<\/ul>\n<h3>FAQ per acquirenti e formulatori<\/h3>\n<p><strong>Why do many wastewater problems resist one-step fixes?<\/strong><br \/>Because the visible symptom is often created by several interacting process variables rather than one isolated cause.<\/p>\n<p><strong>Should operational changes be evaluated only by one output indicator?<\/strong><br \/>Usually no. A stable treatment decision should consider process balance, compliance, sludge behavior, and the effect on downstream steps as well.<\/p>\n<p><!-- lc-commercial-end --><\/p>","protected":false},"excerpt":{"rendered":"<p>A sewage treatment plant needs to add various chemicals during the treatment process to ensure that the effluent quality meets the standards. Commonly used chemicals include coagulants, flocculants, carbon sources,<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[168],"tags":[],"class_list":["post-7830","post","type-post","status-publish","format-standard","hentry","category-water-treatment"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What are the ratios of commonly used chemicals and operating techniques in sewage treatment plants? - Longchang Chemical<\/title>\n<meta name=\"description\" content=\"A sewage treatment plant needs to add various chemicals during the treatment process to ensure that the effluent quality meets the standards. Commonly u...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longchangchemical.com\/it\/what-are-the-ratios-of-commonly-used-chemicals\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What are the ratios of commonly used chemicals and operating techniques in sewage treatment plants? - Longchang Chemical\" \/>\n<meta property=\"og:description\" content=\"A sewage treatment plant needs to add various chemicals during the treatment process to ensure that the effluent quality meets the standards. Commonly u...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longchangchemical.com\/it\/what-are-the-ratios-of-commonly-used-chemicals\/\" \/>\n<meta property=\"og:site_name\" content=\"Longchang Chemical\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-06T10:57:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-28T09:55:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2024\/02\/logo-jpeg.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Longchang Chemical\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/\"},\"author\":{\"name\":\"Longchang Chemical\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e\"},\"headline\":\"What are the ratios of commonly used chemicals and operating techniques in sewage treatment plants?\",\"datePublished\":\"2025-01-06T10:57:04+00:00\",\"dateModified\":\"2026-04-28T09:55:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/\"},\"wordCount\":1402,\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"articleSection\":[\"Water treatment\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/\",\"url\":\"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/\",\"name\":\"What are the ratios of commonly used chemicals and operating techniques in sewage treatment plants? - Longchang Chemical\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/#website\"},\"datePublished\":\"2025-01-06T10:57:04+00:00\",\"dateModified\":\"2026-04-28T09:55:32+00:00\",\"description\":\"A sewage treatment plant needs to add various chemicals during the treatment process to ensure that the effluent quality meets the standards. Commonly u...\",\"breadcrumb\":{\"@id\":\"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/longchangchemical.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What are the ratios of commonly used chemicals and operating techniques in sewage treatment plants?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/longchangchemical.com\/#website\",\"url\":\"https:\/\/longchangchemical.com\/\",\"name\":\"Longchang Chemical\",\"description\":\"China chemical manufacturer \uff06 supplier\",\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/longchangchemical.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/longchangchemical.com\/#organization\",\"name\":\"Longchang Chemical\",\"url\":\"https:\/\/longchangchemical.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"contentUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"width\":512,\"height\":512,\"caption\":\"Longchang Chemical\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e\",\"name\":\"Longchang Chemical\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g\",\"caption\":\"Longchang Chemical\"},\"sameAs\":[\"https:\/\/longchangchemical.com\"],\"url\":\"https:\/\/longchangchemical.com\/it\/author\/infolongchangchemical-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Quali sono i rapporti tra le sostanze chimiche e le tecniche operative comunemente utilizzate negli impianti di trattamento delle acque reflue? - Prodotto chimico Longchang","description":"A sewage treatment plant needs to add various chemicals during the treatment process to ensure that the effluent quality meets the standards. Commonly u...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longchangchemical.com\/it\/what-are-the-ratios-of-commonly-used-chemicals\/","og_locale":"it_IT","og_type":"article","og_title":"What are the ratios of commonly used chemicals and operating techniques in sewage treatment plants? - Longchang Chemical","og_description":"A sewage treatment plant needs to add various chemicals during the treatment process to ensure that the effluent quality meets the standards. Commonly u...","og_url":"https:\/\/longchangchemical.com\/it\/what-are-the-ratios-of-commonly-used-chemicals\/","og_site_name":"Longchang Chemical","article_published_time":"2025-01-06T10:57:04+00:00","article_modified_time":"2026-04-28T09:55:32+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2024\/02\/logo-jpeg.jpg","type":"image\/jpeg"}],"author":"Longchang Chemical","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/#article","isPartOf":{"@id":"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/"},"author":{"name":"Longchang Chemical","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e"},"headline":"What are the ratios of commonly used chemicals and operating techniques in sewage treatment plants?","datePublished":"2025-01-06T10:57:04+00:00","dateModified":"2026-04-28T09:55:32+00:00","mainEntityOfPage":{"@id":"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/"},"wordCount":1402,"publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"articleSection":["Water treatment"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/","url":"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/","name":"Quali sono i rapporti tra le sostanze chimiche e le tecniche operative comunemente utilizzate negli impianti di trattamento delle acque reflue? - Prodotto chimico Longchang","isPartOf":{"@id":"https:\/\/longchangchemical.com\/#website"},"datePublished":"2025-01-06T10:57:04+00:00","dateModified":"2026-04-28T09:55:32+00:00","description":"A sewage treatment plant needs to add various chemicals during the treatment process to ensure that the effluent quality meets the standards. Commonly u...","breadcrumb":{"@id":"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/longchangchemical.com\/what-are-the-ratios-of-commonly-used-chemicals\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/longchangchemical.com\/"},{"@type":"ListItem","position":2,"name":"What are the ratios of commonly used chemicals and operating techniques in sewage treatment plants?"}]},{"@type":"WebSite","@id":"https:\/\/longchangchemical.com\/#website","url":"https:\/\/longchangchemical.com\/","name":"Longchang Chemical","description":"Cina produttore di prodotti chimici \uff06 fornitore","publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longchangchemical.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/longchangchemical.com\/#organization","name":"Longchang Chemical","url":"https:\/\/longchangchemical.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/","url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","contentUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","width":512,"height":512,"caption":"Longchang Chemical"},"image":{"@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e","name":"Longchang Chemical","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g","caption":"Longchang Chemical"},"sameAs":["https:\/\/longchangchemical.com"],"url":"https:\/\/longchangchemical.com\/it\/author\/infolongchangchemical-com\/"}]}},"_links":{"self":[{"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/posts\/7830","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/comments?post=7830"}],"version-history":[{"count":3,"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/posts\/7830\/revisions"}],"predecessor-version":[{"id":9430,"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/posts\/7830\/revisions\/9430"}],"wp:attachment":[{"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/media?parent=7830"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/categories?post=7830"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/longchangchemical.com\/it\/wp-json\/wp\/v2\/tags?post=7830"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}