{"id":3220,"date":"2020-09-11T07:03:33","date_gmt":"2020-09-11T07:03:33","guid":{"rendered":"https:\/\/longchangchemical.com\/?p=3220"},"modified":"2026-04-28T10:41:46","modified_gmt":"2026-04-28T10:41:46","slug":"analytical-instruments-1","status":"publish","type":"post","link":"https:\/\/longchangchemical.com\/hu\/analytical-instruments-1\/","title":{"rendered":"A Longchang Chemical Laboratory \u00e1ltal v\u00e1s\u00e1rolt analitikai m\u0171szerek\uff081\uff09"},"content":{"rendered":"<h4 class=\"wp-block-heading\">1. ICP<\/h4>\n\n<!-- lc-qa-start -->\n<p><strong>Quick answer:<\/strong> For general industrial-chemical topics, the safest commercial decision usually comes from checking application fit, specification, process compatibility, and handling requirements together instead of relying on one simplified rule.<\/p>\n<!-- lc-qa-end -->\n\n\n\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1030\" height=\"726\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png\" alt=\"\" class=\"wp-image-3231\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png 1030w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-300x212.png 300w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-768x542.png 768w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-600x423.png 600w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer.png 1269w\" sizes=\"(max-width: 1030px) 100vw, 1030px\" \/><\/figure>\n\n\n\n<h6 class=\"wp-block-heading\">Angol elnevez\u00e9s: Inductively Coupled Plasma-Atomic Emission Spectrometer (indukt\u00edvan kapcsolt plazma-atomemisszi\u00f3s spektrom\u00e9ter)<br>Modell: 7<br>Gy\u00e1rt\u00f3: Leeman Company<br>Eredet: Egyes\u00fclt \u00c1llamok<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Technikai mutat\u00f3k: Stabilit\u00e1s: \u22641,0%; Ism\u00e9telhet\u0151s\u00e9g \u22641,0%;<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">\u00c9rz\u00e9kel\u00e9si hat\u00e1r: \u03bcg\/L~\u03bcg\/mL Hull\u00e1mhossz-tartom\u00e1ny:  CMOS szil\u00e1rdtest detektor.<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Funkci\u00f3: A peri\u00f3dusos rendszer 68 elem\u00e9nek min\u0151s\u00e9gi \u00e9s mennyis\u00e9gi elemz\u00e9se. A kvantitat\u00edv elemz\u00e9s 0,01-100 \u03bcg\/ml (ppm) koncentr\u00e1ci\u00f3tartom\u00e1nyban k\u00e9pes elemezni a mint\u00e1kat, ak\u00e1r 0,01 ppm pontoss\u00e1ggal, \u00e9s egyidej\u0171leg mintainjekci\u00f3t is v\u00e9gezhet A mint\u00e1ban l\u00e9v\u0151 t\u00f6bb elemet detekt\u00e1lja.<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Elv: A mintaoldat elp\u00e1rolg\u00e1sa \u00e9s elg\u00e1zos\u00edt\u00e1sa ut\u00e1n az elemek mind g\u00e1zatomok form\u00e1j\u00e1ban l\u00e9teznek. Plazma gerjeszt\u00e9s hat\u00e1s\u00e1ra a g\u00e1znem\u0171 atomok a gerjesztett \u00e1llapotb\u00f3l visszat\u00e9rnek az alap\u00e1llapotba, \u00e9s sug\u00e1rz\u00e1st hoznak l\u00e9tre. Mivel a k\u00fcl\u00f6nb\u00f6z\u0151 elemek energiaszintjei elt\u00e9r\u0151ek, saj\u00e1t jellegzetes sug\u00e1rz\u00e1si vonalakkal rendelkeznek, ICP A m\u0171szer a spektrumban l\u00e9v\u0151 egyes vonalak hull\u00e1mhossz\u00e1t \u00e9s intenzit\u00e1s\u00e1t m\u00e9ri az elem t\u00edpus\u00e1nak \u00e9s koncentr\u00e1ci\u00f3j\u00e1nak meghat\u00e1roz\u00e1s\u00e1hoz, hogy min\u0151s\u00e9gi \u00e9s mennyis\u00e9gi elemz\u00e9st v\u00e9gezzen.<\/h6>\n\n\n\n<h4 class=\"wp-block-heading\">2. XRD<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1030\" height=\"773\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/X-Ray-Powder-Diffractometer-1030x773.jpg\" alt=\"\" class=\"wp-image-3232\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/X-Ray-Powder-Diffractometer-1030x773.jpg 1030w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/X-Ray-Powder-Diffractometer-300x225.jpg 300w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/X-Ray-Powder-Diffractometer-768x576.jpg 768w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/X-Ray-Powder-Diffractometer-600x450.jpg 600w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/X-Ray-Powder-Diffractometer.jpg 1269w\" sizes=\"(max-width: 1030px) 100vw, 1030px\" \/><\/figure>\n\n\n\n<h6 class=\"wp-block-heading\">Angol n\u00e9v: X-Ray Powder Diffractometer (r\u00f6ntgenpor-diffraktom\u00e9ter)<br>Modell: D2 PHASER<br>Gy\u00e1rt\u00f3: Bruker<br>Eredet: N\u00e9metorsz\u00e1g<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Technikai mutat\u00f3k: Theta \/ Theta f\u00fcgg\u0151leges goniom\u00e9ter;<br>2Theta sz\u00f6gtartom\u00e1ny: -3~160\u00b0;<br>A minim\u00e1lis l\u00e9p\u00e9ssz\u00f6g 0,002;<br>Nincs sz\u00fcks\u00e9g f\u00e9nyre; Cr\/Co\/Cu c\u00e9lt\u00e1rgy, szabv\u00e1nyos m\u00e9ret\u0171 f\u00e9nycs\u0151;<br>Nincs sz\u00fcks\u00e9g k\u00fcls\u0151 sz\u00e1m\u00edt\u00f3g\u00e9pre, a m\u0171szer vez\u00e9rl\u0151 \u00e9s adatgy\u0171jt\u0151 rendszer integr\u00e1lt kialak\u00edt\u00e1sa;<br>Nincs sz\u00fcks\u00e9g k\u00fcls\u0151 v\u00edzh\u0171t\u00e9sre;<br>Nincs sz\u00fcks\u00e9g el\u0151zetes kalibr\u00e1l\u00e1sra;<br>Gener\u00e1tor teljes\u00edtm\u00e9ny 300W, h\u00e1l\u00f3zati fesz\u00fclts\u00e9g 90-250V, 50-60Hz, plug and play.<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Funkci\u00f3: A diffrakci\u00f3s cs\u00facs helyzete \u00e9s a f\u00e9lmagass\u00e1g sz\u00e9less\u00e9ge alapj\u00e1n hat\u00e1rozza meg a por krist\u00e1lyszerkezet\u00e9t \u00e9s szemcsem\u00e9ret\u00e9t. A szabv\u00e1nyos k\u00e1rtyat\u00e1rral val\u00f3 \u00f6sszehasonl\u00edt\u00e1ssal az ismeretlen minta szerkezet\u00e9re \u00e9s \u00f6sszet\u00e9tel\u00e9re lehet k\u00f6vetkeztetni, \u00e9s a f\u00e1ziselemz\u00e9s pontosan elv\u00e9gezhet\u0151. Min\u0151s\u00e9gi elemz\u00e9s, mennyis\u00e9gi elemz\u00e9s.<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Elv: A krist\u00e1lyos anyagok eset\u00e9ben, ha a m\u00e9rend\u0151 krist\u00e1ly a bees\u0151 r\u00f6ntgensug\u00e1rral k\u00fcl\u00f6nb\u00f6z\u0151 sz\u00f6gben \u00e1ll, akkor a Bragg-diffrakci\u00f3val tal\u00e1lkoz\u00f3 krist\u00e1lys\u00edk lesz detekt\u00e1lhat\u00f3. Ez az XRD-spektrumban elt\u00e9r\u0151 diffrakci\u00f3s intenzit\u00e1s\u00fa diffrakci\u00f3s cs\u00facsokk\u00e9nt jelenik meg. A m\u00e9rt A diffrakci\u00f3s cs\u00facsok alapj\u00e1n lehet k\u00f6vetkeztetni a krist\u00e1lyok szerkezet\u00e9re. Ugyanakkor a k\u00fcl\u00f6nb\u00f6z\u0151 elemekb\u0151l \u00e1ll\u00f3 krist\u00e1lyok krist\u00e1lys\u00edkjai k\u00f6z\u00f6tti k\u00fcl\u00f6nbs\u00e9g miatt a diffrakci\u00f3s cs\u00facsok helyzete is elt\u00e9r\u0151. Az egym\u00e1shoz illeszked\u0151 elemek detekt\u00e1l\u00e1si eszk\u00f6zei \u00f6sszehasonl\u00edthat\u00f3k ismert krist\u00e1lyokkal. Az amorf anyagok eset\u00e9ben, mivel a krist\u00e1lyszerkezetben nincs hossz\u00fa t\u00e1v\u00fa rendezetts\u00e9g, hanem n\u00e9h\u00e1ny atom r\u00f6vid t\u00e1v\u00fa rendezetts\u00e9ge, az XRD-mint\u00e1zatban n\u00e9h\u00e1ny diff\u00faz sz\u00f3r\u00e1s\u00fa cs\u00facs jelenik meg.<\/h6>\n\n\n\n<h4 class=\"wp-block-heading\">3. SEM+EDX<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1030\" height=\"773\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Electron-Microscope-1030x773.png\" alt=\"\" class=\"wp-image-3233\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Electron-Microscope-1030x773.png 1030w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Electron-Microscope-300x225.png 300w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Electron-Microscope-768x576.png 768w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Electron-Microscope-600x450.png 600w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Electron-Microscope.png 1269w\" sizes=\"(max-width: 1030px) 100vw, 1030px\" \/><\/figure>\n\n\n\n<h6 class=\"wp-block-heading\">Angol n\u00e9v: Electron Microscope<br>Modell: Pro X<br>Gy\u00e1rt\u00f3: PHENOM<br>Eredet: Hollandia<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Technikai mutat\u00f3k: Elektronmikroszk\u00f3p: optikai mikroszk\u00f3p: 20-135-sz\u00f6r\u00f6s nagy\u00edt\u00e1s; elektronmikroszk\u00f3p: Elektronelektronmikroszk\u00f3p: 150 000-szeres; detektor: Nagy \u00e9rz\u00e9kenys\u00e9g\u0171 n\u00e9gy szekci\u00f3s visszasz\u00f3rt elektron detektor; Sz\u00e1l anyag: (10 kV) , szekunder elektron k\u00e9pfelbont\u00e1sa 8 nm (10 kV); gyors\u00edt\u00f3fesz\u00fclts\u00e9g: 5 kV-15 kV folyamatosan \u00e1ll\u00edthat\u00f3; v\u00e1kuumid\u0151: kevesebb mint 15 m\u00e1sodperc; detekt\u00e1l\u00f3 elem tartom\u00e1nya: (5)-Am (95) elemek; Energiaspektrum detektor: szil\u00edcium drift detektor (SDD); h\u0171t\u00e9si m\u00f3dszer: nem foly\u00e9kony nitrog\u00e9n Peltier hat\u00e1s\u00fa elektromos h\u0171t\u00e9s; energiafelbont\u00e1s: (Mn Ka\u03b1); detektorkrist\u00e1ly akt\u00edv ter\u00fclete: &lt;123 eV (Mn Ka\u03b1): 25 mm2<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Funkci\u00f3: A minta fel\u00fclet\u00e9nek morfol\u00f3gi\u00e1j\u00e1t k\u00f6zvetlen\u00fcl megfigyelheti aranysz\u00f3r\u00e1s n\u00e9lk\u00fcl, a minta fel\u00fcleti szerkezet\u00e9nek elpuszt\u00edt\u00e1sa n\u00e9lk\u00fcl, \u00e9s ugyanakkor min\u0151s\u00e9gi \u00e9s mennyis\u00e9gi inform\u00e1ci\u00f3kat kaphat a minta fel\u00fcleti elemeir\u0151l.<\/h6>\n\n\n\n<h4 class=\"wp-block-heading\">4. FTIR<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1030\" height=\"687\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fourier-Transform-Infrared-Spectrometer_\u7231\u5947\u827a-1030x687.jpg\" alt=\"\" class=\"wp-image-3227\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fourier-Transform-Infrared-Spectrometer_\u7231\u5947\u827a-1030x687.jpg 1030w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fourier-Transform-Infrared-Spectrometer_\u7231\u5947\u827a-300x200.jpg 300w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fourier-Transform-Infrared-Spectrometer_\u7231\u5947\u827a-768x512.jpg 768w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fourier-Transform-Infrared-Spectrometer_\u7231\u5947\u827a-600x400.jpg 600w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fourier-Transform-Infrared-Spectrometer_\u7231\u5947\u827a.jpg 1125w\" sizes=\"(max-width: 1030px) 100vw, 1030px\" \/><\/figure>\n\n\n\n<h6 class=\"wp-block-heading\">Angol n\u00e9v: Fourier Transform Infrared Spectrometer (Fourier-transzform\u00e1ci\u00f3s infrav\u00f6r\u00f6s spektrom\u00e9ter)<br>Modell: Tensor 27<br>Gy\u00e1rt\u00f3: Bruker<br>Eredet: N\u00e9metorsz\u00e1g<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Technikai mutat\u00f3k: Hull\u00e1msz\u00e1m tartom\u00e1ny: Felbont\u00e1s: 4000-400 cm-1: ROCKSOLID interferom\u00e9ter, kiv\u00e1l\u00f3 szeizmikus teljes\u00edtm\u00e9ny, karbantart\u00e1smentes; kombin\u00e1lhat\u00f3 infrav\u00f6r\u00f6s mikroszk\u00f3ppal , termikus s\u00falyvesztes\u00e9g, g\u00e1zkromatogr\u00e1fia, k\u00e9tsz\u00edn\u0171 rezg\u00e9spark stb.; oper\u00e1ci\u00f3s rendszer: ROCKSOLID interferom\u00e9ter, kiv\u00e1l\u00f3 szeizmikus teljes\u00edtm\u00e9ny, karbantart\u00e1smentes; kombin\u00e1lhat\u00f3 infrav\u00f6r\u00f6s mikroszk\u00f3ppal , termikus s\u00falyvesztes\u00e9g, g\u00e1zkromatogr\u00e1fia, k\u00e9tsz\u00edn\u0171 rezg\u00e9spark stb: OPUS\/IR<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Funkci\u00f3: A szil\u00e1rd, g\u00e1z \u00e9s foly\u00e9kony mint\u00e1k infrav\u00f6r\u00f6s spektrum\u00e1nak m\u00e9r\u00e9s\u00e9re \u00e9s a helysz\u00edni reakci\u00f3folyamatok m\u00e9r\u00e9s\u00e9re szolg\u00e1l, hogy a mint\u00e1ban k\u00fcl\u00f6nb\u00f6z\u0151 k\u00f6t\u00e9sform\u00e1kat \u00e9s k\u00f6lcs\u00f6nhat\u00e1sokat kapjunk, \u00e9s ez alapj\u00e1n megval\u00f3s\u00edtsuk a vegy\u00fclet \u00f6sszet\u00e9tel\u00e9nek azonos\u00edt\u00e1s\u00e1t, a vegy\u00fclet szerkezet\u00e9nek elemz\u00e9s\u00e9t \u00e9s a minta k\u00e9miai tulajdons\u00e1gait.<\/h6>\n\n\n\n<h4 class=\"wp-block-heading\">5. FL<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1030\" height=\"773\" src=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fluorescence-Spectroscopy1-1030x773.jpg\" alt=\"\" class=\"wp-image-3234\" srcset=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fluorescence-Spectroscopy1-1030x773.jpg 1030w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fluorescence-Spectroscopy1-300x225.jpg 300w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fluorescence-Spectroscopy1-768x576.jpg 768w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fluorescence-Spectroscopy1-600x450.jpg 600w, https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Fluorescence-Spectroscopy1.jpg 1269w\" sizes=\"(max-width: 1030px) 100vw, 1030px\" \/><\/figure>\n\n\n\n<h6 class=\"wp-block-heading\">Angol neve: Fluoreszcencia spektroszk\u00f3pia<br>Modell: F7000<br>Gy\u00e1rt\u00f3: Hitachi<br>Eredet: Jap\u00e1n<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Technikai mutat\u00f3k: \u00c9rz\u00e9kenys\u00e9g: gerjeszt\u00e9si emisszi\u00f3s hull\u00e1mhossz-tartom\u00e1ny: 200-900 nm; \u00e9rz\u00e9kenys\u00e9g: S\/N \uff1e800 (RMS); S\/N \uff1e250 (PP); v\u00edz Raman-cs\u00facs\u00e1t haszn\u00e1ljuk, gerjeszt\u00e9si hull\u00e1mhossz 350 nm, spektr\u00e1lis s\u00e1vsz\u00e9less\u00e9g 5 nm, v\u00e1laszid\u0151 2 s; Felbont\u00e1s: 1,0 nm hull\u00e1mhossz pontoss\u00e1g: 1 nm; hull\u00e1mhossz p\u00e1szt\u00e1z\u00e1si sebess\u00e9g: 30\/ 60\/ 240\/ 1200\/ 2400\/ 12000\/ 30000\/ 60000 nm\/perc.<\/h6>\n\n\n\n<h6 class=\"wp-block-heading\">Funkci\u00f3: Lumineszcens anyagok fluoreszcencia gerjeszt\u00e9si spektrum\u00e1nak, fluoreszcencia emisszi\u00f3s spektrum\u00e1nak, h\u00e1romdimenzi\u00f3s spektrum\u00e1nak stb. m\u00e9r\u00e9se. H\u00e1romdimenzi\u00f3s id\u0151szkennel\u00e9si vizsg\u00e1latot \u00e9s fluoreszcencia \u00e9lettartam vizsg\u00e1latot is v\u00e9gezhet.<\/h6>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>L\u00e9pjen kapcsolatba vel\u00fcnk most!<\/strong><\/h4>\n\n\n\n<h6 class=\"wp-block-heading\">Elfogadjuk az egyedi szolg\u00e1ltat\u00e1sokat, \u00e1ltal\u00e1ban 24 \u00f3r\u00e1n bel\u00fcl felvessz\u00fck \u00d6nnel a kapcsolatot. A munkaid\u0151ben ( 8:30-18:00 UTC+8 H.~Szombat ) az info@longchangchemical.com e-mail c\u00edmen is k\u00fcldhet e-mailt, vagy haszn\u00e1lhatja a weboldal \u00e9l\u0151 chatj\u00e9t, hogy gyors v\u00e1laszt kapjon.<\/h6>\n\n\n\n<h4 class=\"wp-block-heading\">Ezt a cikket a Longchang Chemical R&amp;D Department \u00edrta. Ha m\u00e1solni \u00e9s \u00fajranyomtatni szeretn\u00e9, k\u00e9rj\u00fck, adja meg a forr\u00e1st.<\/h4>\n\n\n<!-- lc-commercial-start -->\n<h2>How technical buyers usually evaluate this chemical topic<\/h2>\n<p>General chemical decisions usually become clearer when teams move from theory to application fit: what the material needs to do, how pure it needs to be, how it behaves in the real process, and what downstream constraints it must satisfy.<\/p>\n<ul>\n<li><strong>Define the use case first:<\/strong> laboratory understanding and industrial purchasing often need different levels of specification detail.<\/li>\n<li><strong>Check process compatibility:<\/strong> handling, blending, stability, and downstream interaction often determine whether a material is practical to use.<\/li>\n<li><strong>Review storage and transport behavior:<\/strong> shelf life, moisture sensitivity, temperature range, and packaging can all matter commercially.<\/li>\n<li><strong>Use sample validation when the application is critical:<\/strong> small-scale confirmation often saves the most time before a full purchasing decision.<\/li>\n<\/ul>\n<h3>Recommended product references<\/h3>\n<ul>\n<li><strong><a href=\"https:\/\/longchangchemical.com\/hu\/product\/photoinitiator-cq\/\">CHLUMINIT CQ<\/a>:<\/strong> A direct reference for visible-light and color-sensitive curing discussions.<\/li>\n<\/ul>\n<h3>FAQ for buyers and formulators<\/h3>\n<p><strong>Why can a material that looks correct on paper still underperform in use?<\/strong><br \/>Because real-world process conditions, substrate interaction, and storage behavior can reveal problems that are not obvious in a simplified specification review.<\/p>\n<p><strong>Should technical chemical selection always start with the lowest-cost option?<\/strong><br \/>Not usually. The lowest purchase price is not always the lowest use cost once process fit, stability, and downstream quality are considered.<\/p>\n<!-- lc-commercial-end -->","protected":false},"excerpt":{"rendered":"<p>1. ICP English name: Inductively Coupled Plasma-Atomic Emission SpectrometerModel: Prodigy 7Manufacturer: Leeman CompanyOrigin: United States Technical indicators: Optical resolution: \u22640.007nm (at 200 nm); Stability: \u22641.0%; Repeatability \u22641.0%; Detection limit: \u03bcg\/L~\u03bcg\/mL<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[106],"tags":[],"class_list":["post-3220","post","type-post","status-publish","format-standard","hentry","category-laboratory-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Analytical Instruments purchased by Longchang Chemical Laboratory\uff081\uff09 - Longchang Chemical<\/title>\n<meta name=\"description\" content=\"1. ICP English name: Inductively Coupled Plasma-Atomic Emission SpectrometerModel: Prodigy 7Manufacturer: Leeman CompanyOrigin: United States Technical...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longchangchemical.com\/hu\/analytical-instruments-1\/\" \/>\n<meta property=\"og:locale\" content=\"hu_HU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Analytical Instruments purchased by Longchang Chemical Laboratory\uff081\uff09 - Longchang Chemical\" \/>\n<meta property=\"og:description\" content=\"1. ICP English name: Inductively Coupled Plasma-Atomic Emission SpectrometerModel: Prodigy 7Manufacturer: Leeman CompanyOrigin: United States Technical...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longchangchemical.com\/hu\/analytical-instruments-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Longchang Chemical\" \/>\n<meta property=\"article:published_time\" content=\"2020-09-11T07:03:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-28T10:41:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1269\" \/>\n\t<meta property=\"og:image:height\" content=\"895\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Longchang Chemical\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/\"},\"author\":{\"name\":\"Longchang Chemical\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e\"},\"headline\":\"Analytical Instruments purchased by Longchang Chemical Laboratory\uff081\uff09\",\"datePublished\":\"2020-09-11T07:03:33+00:00\",\"dateModified\":\"2026-04-28T10:41:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/\"},\"wordCount\":1046,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png\",\"articleSection\":[\"Laboratory News\"],\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/longchangchemical.com\/analytical-instruments-1\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/\",\"url\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/\",\"name\":\"Analytical Instruments purchased by Longchang Chemical Laboratory\uff081\uff09 - Longchang Chemical\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png\",\"datePublished\":\"2020-09-11T07:03:33+00:00\",\"dateModified\":\"2026-04-28T10:41:46+00:00\",\"description\":\"1. ICP English name: Inductively Coupled Plasma-Atomic Emission SpectrometerModel: Prodigy 7Manufacturer: Leeman CompanyOrigin: United States Technical...\",\"breadcrumb\":{\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/#breadcrumb\"},\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/longchangchemical.com\/analytical-instruments-1\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/#primaryimage\",\"url\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png\",\"contentUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/longchangchemical.com\/analytical-instruments-1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/longchangchemical.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Analytical Instruments purchased by Longchang Chemical Laboratory\uff081\uff09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/longchangchemical.com\/#website\",\"url\":\"https:\/\/longchangchemical.com\/\",\"name\":\"Longchang Chemical\",\"description\":\"China chemical manufacturer \uff06 supplier\",\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/longchangchemical.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"hu\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/longchangchemical.com\/#organization\",\"name\":\"Longchang Chemical\",\"url\":\"https:\/\/longchangchemical.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"contentUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"width\":512,\"height\":512,\"caption\":\"Longchang Chemical\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e\",\"name\":\"Longchang Chemical\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g\",\"caption\":\"Longchang Chemical\"},\"sameAs\":[\"https:\/\/longchangchemical.com\"],\"url\":\"https:\/\/longchangchemical.com\/hu\/author\/infolongchangchemical-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"A Longchang Chemical Laboratory \u00e1ltal v\u00e1s\u00e1rolt analitikai m\u0171szerek\uff081\uff09 - Longchang Chemical","description":"1. ICP English name: Inductively Coupled Plasma-Atomic Emission SpectrometerModel: Prodigy 7Manufacturer: Leeman CompanyOrigin: United States Technical...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longchangchemical.com\/hu\/analytical-instruments-1\/","og_locale":"hu_HU","og_type":"article","og_title":"Analytical Instruments purchased by Longchang Chemical Laboratory\uff081\uff09 - Longchang Chemical","og_description":"1. ICP English name: Inductively Coupled Plasma-Atomic Emission SpectrometerModel: Prodigy 7Manufacturer: Leeman CompanyOrigin: United States Technical...","og_url":"https:\/\/longchangchemical.com\/hu\/analytical-instruments-1\/","og_site_name":"Longchang Chemical","article_published_time":"2020-09-11T07:03:33+00:00","article_modified_time":"2026-04-28T10:41:46+00:00","og_image":[{"width":1269,"height":895,"url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer.png","type":"image\/png"}],"author":"Longchang Chemical","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/#article","isPartOf":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/"},"author":{"name":"Longchang Chemical","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e"},"headline":"Analytical Instruments purchased by Longchang Chemical Laboratory\uff081\uff09","datePublished":"2020-09-11T07:03:33+00:00","dateModified":"2026-04-28T10:41:46+00:00","mainEntityOfPage":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/"},"wordCount":1046,"commentCount":0,"publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"image":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/#primaryimage"},"thumbnailUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png","articleSection":["Laboratory News"],"inLanguage":"hu","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/longchangchemical.com\/analytical-instruments-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/","url":"https:\/\/longchangchemical.com\/analytical-instruments-1\/","name":"A Longchang Chemical Laboratory \u00e1ltal v\u00e1s\u00e1rolt analitikai m\u0171szerek\uff081\uff09 - Longchang Chemical","isPartOf":{"@id":"https:\/\/longchangchemical.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/#primaryimage"},"image":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/#primaryimage"},"thumbnailUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png","datePublished":"2020-09-11T07:03:33+00:00","dateModified":"2026-04-28T10:41:46+00:00","description":"1. ICP English name: Inductively Coupled Plasma-Atomic Emission SpectrometerModel: Prodigy 7Manufacturer: Leeman CompanyOrigin: United States Technical...","breadcrumb":{"@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/#breadcrumb"},"inLanguage":"hu","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longchangchemical.com\/analytical-instruments-1\/"]}]},{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/#primaryimage","url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png","contentUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/09\/Inductively-Coupled-Plasma-Atomic-Emission-Spectrometer-1030x726.png"},{"@type":"BreadcrumbList","@id":"https:\/\/longchangchemical.com\/analytical-instruments-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/longchangchemical.com\/"},{"@type":"ListItem","position":2,"name":"Analytical Instruments purchased by Longchang Chemical Laboratory\uff081\uff09"}]},{"@type":"WebSite","@id":"https:\/\/longchangchemical.com\/#website","url":"https:\/\/longchangchemical.com\/","name":"Longchang Chemical","description":"K\u00edna k\u00e9miai gy\u00e1rt\u00f3 \uff06 sz\u00e1ll\u00edt\u00f3","publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longchangchemical.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"hu"},{"@type":"Organization","@id":"https:\/\/longchangchemical.com\/#organization","name":"Longchang Chemical","url":"https:\/\/longchangchemical.com\/","logo":{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/","url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","contentUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","width":512,"height":512,"caption":"Longchang Chemical"},"image":{"@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/ecb1ad846136c6f1ca534b62978c6a8e","name":"Longchang Chemical","image":{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c1e84ee0759373263198c58e8f338f80?s=96&d=mm&r=g","caption":"Longchang Chemical"},"sameAs":["https:\/\/longchangchemical.com"],"url":"https:\/\/longchangchemical.com\/hu\/author\/infolongchangchemical-com\/"}]}},"_links":{"self":[{"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/posts\/3220","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/comments?post=3220"}],"version-history":[{"count":4,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/posts\/3220\/revisions"}],"predecessor-version":[{"id":9076,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/posts\/3220\/revisions\/9076"}],"wp:attachment":[{"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/media?parent=3220"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/categories?post=3220"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/tags?post=3220"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}