{"id":10617,"date":"2026-07-14T00:00:49","date_gmt":"2026-07-14T00:00:49","guid":{"rendered":"https:\/\/longchangchemical.com\/?p=10617"},"modified":"2026-08-08T07:15:06","modified_gmt":"2026-08-08T07:15:06","slug":"architectural-coating-additives","status":"publish","type":"post","link":"https:\/\/longchangchemical.com\/hu\/architectural-coating-additives\/","title":{"rendered":"Architectural Coating Additives: Water vs Solvent Routes"},"content":{"rendered":"<p><strong>Architectural coating additives must pass a water-versus-solvent system gate before product selection.<\/strong> DP-D2791 is the documented waterborne pigment-dispersion route; DP-D200R is explicitly solvent-based, even though its page recommends architectural coatings; WD-D547 is a broad-system wetting and anti-cratering route. Treating DP-D200R as a universal architectural dispersant is a formulation error.<\/p>\n<p>Next locate the first failed stage: pigment grind, application wetting, or the dry wall-paint performance package. Additives can improve dispersion or surface formation, but they cannot replace correct pigment volume concentration, rheology, binder, substrate preparation, hiding, scrub resistance, stain resistance, or exterior durability.<\/p>\n<h2>Architectural coating system gate<\/h2>\n<figure>\n<table>\n<thead>\n<tr>\n<th>System and failure<\/th>\n<th>Evidence to hold constant<\/th>\n<th>First route<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Waterborne paint: grind viscosity, slow fineness, low color strength, or settling<\/td>\n<td>Pigment\/filler lot, pH, solids, sequence, shear, and letdown<\/td>\n<td>DP-D2791<\/td>\n<\/tr>\n<tr>\n<td>Solvent-borne paint: the same verified dispersion bottleneck<\/td>\n<td>Resin\/solvent balance, pigment, sequence, shear, and temperature<\/td>\n<td>DP-D200R<\/td>\n<\/tr>\n<tr>\n<td>Water, solvent, solvent-free, or UV: wetting\/cratering after substrate control<\/td>\n<td>Substrate, contamination, viscosity, film build, and application<\/td>\n<td>WD-D547<\/td>\n<\/tr>\n<tr>\n<td>Scrub, washability, sag, hiding, or weathering fails without a liquid defect<\/td>\n<td>Binder\/PVC\/rheology\/film build\/cure package<\/td>\n<td>Reformulate the property package before additive escalation<\/td>\n<\/tr>\n<\/tbody>\n<\/table><figcaption>Original architectural-coating route map: choose the carrier system first, then separate pigment dispersion from surface wetting and dry-film performance.<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th>Term\u00e9k<\/th>\n<th>Published system<\/th>\n<th>Supplier use guidance<\/th>\n<th>Boundary<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><a href=\"https:\/\/longchangchemical.com\/hu\/product\/agesin-dp-d2791-dispersant\/\"><strong>CHLUMICRYL\u00ae DP-D2791<\/strong><\/a><\/td>\n<td>Water-based; inorganic and organic pigments<\/td>\n<td>Add to grinding material before pigment; pigment-specific guidance<\/td>\n<td>Waterborne route; determine dosage by pigment and current TDS<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/longchangchemical.com\/hu\/product\/agesin-dp-d200r\/\"><strong>CHLUMICRYL\u00ae DP-D200R<\/strong><\/a><\/td>\n<td>Solvent-based only; architectural, industrial, anti-corrosion; 50% active in DPM<\/td>\n<td>Add to grind before pigment<\/td>\n<td>Do not use as the waterborne dispersant<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/longchangchemical.com\/hu\/product\/agesin-wd-d547-wetting-agent\/\"><strong>CHLUMICRYL\u00ae WD-D547<\/strong><\/a><\/td>\n<td>Water, solvent, solvent-free, and UV; wetting, anti-cratering and leveling<\/td>\n<td>0.1\u20130.5%; direct or diluted addition<\/td>\n<td>Does not replace architectural rheology or durability design<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Define the paint and customer problem<\/h2>\n<p>Record interior or exterior use, flat\/eggshell\/semi-gloss finish, waterborne or solvent vehicle, substrate, primer, application method, tint base, pigment volume concentration, target hiding, sag, leveling, open time, scrub, stain, blocking, touch-up, weathering, and VOC\/regulatory requirements. \u201cArchitectural coating\u201d is too broad to support one additive ranking.<\/p>\n<p>Separate a factory manufacturing issue from an applicator complaint. High mill-base viscosity needs a grind study; roller spatter, lap marks, poor touch-up, sag, and brush drag require rheology and application analysis; craters on one wall may come from contamination.<\/p>\n<h2>Use DP-D2791 for a waterborne dispersion bottleneck<\/h2>\n<p>DP-D2791 is the relevant first screen for waterborne architectural pigment dispersion. Its page supports inorganic and organic pigments, VOC- and APEO-free formulation, viscosity reduction, pigment spreading, and use across water-based resin systems. Add it to the grinding material before pigment.<\/p>\n<p>Use pigment-specific dosage guidance and compare fineness, grind time, viscosity, color strength, rub-up, hiding, gloss\/sheen, settling, hard pack, tint acceptance, and storage. A dosage suited to titanium dioxide may not suit carbon black, iron oxide, or an organic color.<\/p>\n<h2>Keep DP-D200R inside the solvent boundary<\/h2>\n<p>DP-D200R can be a legitimate architectural route only when the paint is solvent-borne. Its public page states a solvent-based application system, 50% active content in dipropylene glycol methyl ether, and addition to the grind before pigment. It also highlights viscosity reduction, color strength, hiding, and bentonite slurry preparation.<\/p>\n<p>Do not infer water compatibility from the word \u201carchitectural.\u201d If the project is waterborne, use a waterborne dispersant route. If it is solvent-borne, verify resin compatibility, solvent balance, grind stability, application, dry time, gloss, and storage.<\/p>\n<h2>Use WD-D547 for confirmed wetting or cratering<\/h2>\n<p>WD-D547 is the broad-system surface route after contamination and substrate preparation are controlled. Its page documents surface-tension reduction, wetting\/spreading, anti-cratering, recoat, defoaming, and leveling properties with 0.1\u20130.5% guidance.<\/p>\n<p>Screen a low-dose ladder and protect sag, leveling, open time, foam, gloss, adhesion, touch-up, and recoat. Better spreading on a laboratory panel does not prove better brush, roller, or spray behavior on porous plaster, drywall, masonry, or previously painted surfaces.<\/p>\n<h2>Build an application-relevant trial<\/h2>\n<ol>\n<li><strong>Separate water and solvent formulas.<\/strong> Never compare DP-D2791 and DP-D200R as interchangeable doses.<\/li>\n<li><strong>Fix raw materials.<\/strong> Hold pigment\/filler lots, binder, PVC, pH or solvent balance, solids, and tint level.<\/li>\n<li><strong>Fix manufacture.<\/strong> Hold order, shear, time, temperature, fineness, letdown, and aging.<\/li>\n<li><strong>Fix application.<\/strong> Use the specified brush, roller, or spray, substrate, spreading rate, temperature, humidity, and recoat.<\/li>\n<li><strong>Measure the end use.<\/strong> Include hiding, sag, leveling, gloss\/sheen, touch-up, scrub, stain, blocking, and storage.<\/li>\n<\/ol>\n<h2>Use recognized measurements without overclaiming<\/h2>\n<p><a href=\"https:\/\/store.astm.org\/standards\/d2486\">ASTM D2486<\/a> measures the relative resistance of wall paints to erosion by repeated scrubbing and notes important reproducibility variables. <a href=\"https:\/\/store.astm.org\/standards\/d2196\">ASTM D2196<\/a> measures apparent viscosity, shear thinning, thixotropy, and post-high-shear behavior. <a href=\"https:\/\/store.astm.org\/d2244-21.html\">ASTM D2244<\/a> covers instrumentally calculated color differences and requires agreed tolerances and calculation procedures.<\/p>\n<p>Use the version and conditions in the customer specification. Add wet\/dry film thickness, coverage, sag, leveling, gloss or sheen, color, rub-up, adhesion, open time, touch-up, stain, scrub, blocking, storage, and exterior exposure where relevant.<\/p>\n<h2>Common architectural-coating errors<\/h2>\n<h3>Using DP-D200R in a waterborne project<\/h3>\n<p>The product page is explicit: DP-D200R is solvent-based. For a waterborne dispersion problem, start with DP-D2791 or another documented waterborne route.<\/p>\n<h3>Trying to repair scrub resistance with wetting additive<\/h3>\n<p>Scrub failure can involve binder, PVC, coalescence, cure, film build, and pigment\/filler balance. WD-D547 should be screened for wetting evidence, not as a substitute for the dry-film package.<\/p>\n<h3>Approving on glass only<\/h3>\n<p>Glass is useful for appearance comparisons but does not represent porous wallboard, plaster, masonry, wood, or aged paint. Confirm the winning formulation on production-relevant substrates and application tools.<\/p>\n<h2>Related architectural guides<\/h2>\n<p>Use the <a href=\"https:\/\/longchangchemical.com\/hu\/dispersants-pigmented-coatings-inks\/\">dispersant guide<\/a> for pigment-specific screening, the <a href=\"https:\/\/longchangchemical.com\/hu\/wetting-additives-coatings-inks\/\">wetting guide<\/a> for surface-energy problems, or the <a href=\"https:\/\/longchangchemical.com\/hu\/coating-fisheye-additive-selection\/\">fisheye guide<\/a> when isolated retraction defects dominate.<\/p>\n<h2>Request an architectural coating shortlist<\/h2>\n<p>Send the water\/solvent system, binder, pigments\/fillers and PVC, tint base, pH or solvent blend, solids, grind equipment, substrate\/primer, application method, spreading rate, cure, current additives, defect evidence, and required scrub, stain, touch-up, blocking, or weathering tests. <a href=\"https:\/\/longchangchemical.com\/hu\/#contact-section\"><strong>Ask Longchang Chemical to compare DP-D2791, DP-D200R, or WD-D547<\/strong><\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Choose architectural coating additives by separating pigment-dispersion viscosity control, substrate wetting and anti-cratering, and final leveling compatibility across CHLUMICRYL\u00ae routes.<\/p>","protected":false},"author":6,"featured_media":10618,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-10617","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Architectural Coating Additives: Water vs Solvent Routes<\/title>\n<meta name=\"description\" content=\"Choose architectural coating additives without crossing system boundaries. Compare waterborne DP-D2791, solvent-only DP-D200R and broad-system WD-D547.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/longchangchemical.com\/hu\/architectural-coating-additives\/\" \/>\n<meta property=\"og:locale\" content=\"hu_HU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Architectural Coating Additives: Water vs Solvent Routes\" \/>\n<meta property=\"og:description\" content=\"Choose architectural coating additives without crossing system boundaries. Compare waterborne DP-D2791, solvent-only DP-D200R and broad-system WD-D547.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/longchangchemical.com\/hu\/architectural-coating-additives\/\" \/>\n<meta property=\"og:site_name\" content=\"Longchang Chemical\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-14T00:00:49+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-08T07:15:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"576\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"marketing@longchang Group\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/\"},\"author\":{\"name\":\"marketing@longchang Group\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/03647a4ce07fdc0e453f27a2b96ccce5\"},\"headline\":\"Architectural Coating Additives: Water vs Solvent Routes\",\"datePublished\":\"2026-07-14T00:00:49+00:00\",\"dateModified\":\"2026-08-08T07:15:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/\"},\"wordCount\":978,\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"hu\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/\",\"url\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/\",\"name\":\"Architectural Coating Additives: Water vs Solvent Routes\",\"isPartOf\":{\"@id\":\"https:\/\/longchangchemical.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg\",\"datePublished\":\"2026-07-14T00:00:49+00:00\",\"dateModified\":\"2026-08-08T07:15:06+00:00\",\"description\":\"Choose architectural coating additives without crossing system boundaries. Compare waterborne DP-D2791, solvent-only DP-D200R and broad-system WD-D547.\",\"breadcrumb\":{\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/#breadcrumb\"},\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/longchangchemical.com\/architectural-coating-additives\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/#primaryimage\",\"url\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg\",\"contentUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg\",\"width\":1024,\"height\":576},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/longchangchemical.com\/architectural-coating-additives\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/longchangchemical.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Architectural Coating Additives: Water vs Solvent Routes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/longchangchemical.com\/#website\",\"url\":\"https:\/\/longchangchemical.com\/\",\"name\":\"Longchang Chemical\",\"description\":\"China chemical manufacturer \uff06 supplier\",\"publisher\":{\"@id\":\"https:\/\/longchangchemical.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/longchangchemical.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"hu\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/longchangchemical.com\/#organization\",\"name\":\"Longchang Chemical\",\"url\":\"https:\/\/longchangchemical.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"contentUrl\":\"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png\",\"width\":512,\"height\":512,\"caption\":\"Longchang Chemical\"},\"image\":{\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/03647a4ce07fdc0e453f27a2b96ccce5\",\"name\":\"marketing@longchang Group\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/a6a906641262cdfd34e337a3fa18594a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/a6a906641262cdfd34e337a3fa18594a?s=96&d=mm&r=g\",\"caption\":\"marketing@longchang Group\"},\"url\":\"https:\/\/longchangchemical.com\/hu\/author\/marketinglongchang-group\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Architectural Coating Additives: Water vs Solvent Routes","description":"Choose architectural coating additives without crossing system boundaries. Compare waterborne DP-D2791, solvent-only DP-D200R and broad-system WD-D547.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/longchangchemical.com\/hu\/architectural-coating-additives\/","og_locale":"hu_HU","og_type":"article","og_title":"Architectural Coating Additives: Water vs Solvent Routes","og_description":"Choose architectural coating additives without crossing system boundaries. Compare waterborne DP-D2791, solvent-only DP-D200R and broad-system WD-D547.","og_url":"https:\/\/longchangchemical.com\/hu\/architectural-coating-additives\/","og_site_name":"Longchang Chemical","article_published_time":"2026-07-14T00:00:49+00:00","article_modified_time":"2026-08-08T07:15:06+00:00","og_image":[{"width":1024,"height":576,"url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg","type":"image\/jpeg"}],"author":"marketing@longchang Group","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/#article","isPartOf":{"@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/"},"author":{"name":"marketing@longchang Group","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/03647a4ce07fdc0e453f27a2b96ccce5"},"headline":"Architectural Coating Additives: Water vs Solvent Routes","datePublished":"2026-07-14T00:00:49+00:00","dateModified":"2026-08-08T07:15:06+00:00","mainEntityOfPage":{"@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/"},"wordCount":978,"publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"image":{"@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/#primaryimage"},"thumbnailUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg","articleSection":["Uncategorized"],"inLanguage":"hu"},{"@type":"WebPage","@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/","url":"https:\/\/longchangchemical.com\/architectural-coating-additives\/","name":"Architectural Coating Additives: Water vs Solvent Routes","isPartOf":{"@id":"https:\/\/longchangchemical.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/#primaryimage"},"image":{"@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/#primaryimage"},"thumbnailUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg","datePublished":"2026-07-14T00:00:49+00:00","dateModified":"2026-08-08T07:15:06+00:00","description":"Choose architectural coating additives without crossing system boundaries. Compare waterborne DP-D2791, solvent-only DP-D200R and broad-system WD-D547.","breadcrumb":{"@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/#breadcrumb"},"inLanguage":"hu","potentialAction":[{"@type":"ReadAction","target":["https:\/\/longchangchemical.com\/architectural-coating-additives\/"]}]},{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/#primaryimage","url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg","contentUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2026\/07\/architectural-coating-additives-hero-1.jpg","width":1024,"height":576},{"@type":"BreadcrumbList","@id":"https:\/\/longchangchemical.com\/architectural-coating-additives\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/longchangchemical.com\/"},{"@type":"ListItem","position":2,"name":"Architectural Coating Additives: Water vs Solvent Routes"}]},{"@type":"WebSite","@id":"https:\/\/longchangchemical.com\/#website","url":"https:\/\/longchangchemical.com\/","name":"Longchang Chemical","description":"K\u00edna k\u00e9miai gy\u00e1rt\u00f3 \uff06 sz\u00e1ll\u00edt\u00f3","publisher":{"@id":"https:\/\/longchangchemical.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/longchangchemical.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"hu"},{"@type":"Organization","@id":"https:\/\/longchangchemical.com\/#organization","name":"Longchang Chemical","url":"https:\/\/longchangchemical.com\/","logo":{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/","url":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","contentUrl":"https:\/\/longchangchemical.com\/wp-content\/uploads\/2020\/08\/cropped-longchang-logo.png","width":512,"height":512,"caption":"Longchang Chemical"},"image":{"@id":"https:\/\/longchangchemical.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/03647a4ce07fdc0e453f27a2b96ccce5","name":"marketing@longchang Csoport","image":{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/longchangchemical.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/a6a906641262cdfd34e337a3fa18594a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a6a906641262cdfd34e337a3fa18594a?s=96&d=mm&r=g","caption":"marketing@longchang Group"},"url":"https:\/\/longchangchemical.com\/hu\/author\/marketinglongchang-group\/"}]}},"_links":{"self":[{"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/posts\/10617","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/comments?post=10617"}],"version-history":[{"count":3,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/posts\/10617\/revisions"}],"predecessor-version":[{"id":11148,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/posts\/10617\/revisions\/11148"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/media\/10618"}],"wp:attachment":[{"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/media?parent=10617"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/categories?post=10617"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/longchangchemical.com\/hu\/wp-json\/wp\/v2\/tags?post=10617"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}